14
7.3. Connection of Mute Switch
Any commercially available push-button switch can be connected to the external control input
terminal.
Note
If the external mute function is not to be used, do not connect any switch to the external control input
terminal.
Base Unit (rear)
1
Push-button switch or the like
1. External mute input device connection
Connect a commercially available push-
button switch or the like.
Compatible wires sizes:
Solid wire:
ø0.41 mm – 0.64 mm
(AWG26 – AWG22)
Stranded wire: 0.13 mm
2
– 0.32 mm
2
(AWG26 – AWG22)
7.3.1. Connection
Step 1.
Strip back the wire insulation by about 10 mm.
Step 2.
While holding open the terminal clamp with a
screwdriver, insert the wire then let go of the terminal
clamp to connect.
Step 3.
Lightly pull on the wires to ensure that they don’t pull out.
To prevent the cores of stranded wires from loosening over time, attach insulated crimp pin terminals
on the ends of the wires.
Recommended ferrule terminals for signal cables
(made by DINKLE ENTERPRISE)
Model Number
a
b
l
1
l
2
DN00308D
1.9 mm
0.8 mm
12 mm
8 mm
DN00508D
2.6 mm
1 mm
14 mm
8 mm
Stripping length:
About 10 mm
Terminal clamp
Insulation sleeve
Contact area
a
b
l2
l1