4-16
Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER)
6.2. Contact Output Setting
Set the contact output to be activated when the NX-100/100S is enabled by other unit or the operation
program. Selecting a contact output will switch the display to the contact output setting screen. Select
"Enable" and set the contact output contents.
This figure represents the NX-100.
(1) Mode
Select Mode from [Standard], [STATUS Output], and [ERROR Output].
Standard:
Provides output by way of control from a PC or contact inputs of other units or original
unit.
STATUS Output: Provides contact output synchronizing with the unit's STATUS indicator operation.
ERROR Output:
Provides contact output synchronizing with the unit's ERROR indicator operation.
Note
To use the Contact bridge function, select [Standard].