Chapter 3
SYSTEM SETTINGS (NX-300 SETTING SOFTWARE)
3-
3. Connection destination
Select the unit to be connected.
Note
Selection is only possible hen T
lient or
is checked in the protocol settings.
4. Baud rate
Select
00 , 1 00 , 3 00 ,
00 or 11 00 .
5. Data length
Set to either bits or bits .
6. Parity
Select [Even], [Odd] or [None].
7. Stop bits
Select [1 bit] or [2 bits].
8. Flow control
Select the type of flow control.
None:
Flow control is not performed.
Xon/Xoff:
Performs software flow control.
ard are
erforms hard are o control.
9. Auto cutoff time [min]
Set the time inter al timeout duration 0 0 minutes before the connected unit is automatically
disconnected following the end of the last communication. The connected unit is not disconnected if the
timeout duration is set to [0]. Valid only when "TCP Server" or "TCP Client" is selected in the protocol
settings.
10. Transmit/Receive raw data.
Tick the checkbo hen transmitting and recei ing ra data. ata ith control information to be utili ed
between NX-100 units is usually transmitted, but raw data communications are generally carried out
ithout such control information. o e er, hen communications ith other connected units are cut off,
this cannot be detected. Valid only when "TCP Server" or "TCP Client" is selected in the protocol settings.
Note
Serial bridge function data can be transmitted at e ery 0 ms inter als or hen its data length becomes 10
bytes within 20 ms.
This serial bridge function cannot be used for the e uipment that communicate ith data less than 10 bytes
long at intervals shorter than 20 ms.
Summary of Contents for NX-300
Page 7: ...Chapter 1 SYSTEM SUMMARY ...
Page 12: ...Chapter 2 INSTALLATION AND CONNECTION ...
Page 23: ...Chapter 3 SYSTEM SETTINGS NX 300 SETTING SOFTWARE ...
Page 113: ...Chapter 4 SETTINGS AND MANAGEMENT BY BROWSER ...
Page 140: ...Chapter 5 SETTINGS NECESSARY WHEN USING THE NX 300 OPERATION SOFTWARE ...
Page 163: ...Chapter 6 APPENDIX ...