7.3. Connection of the RM-1200's Push-in Terminal Block 

1. Strip the cable sheath 9 mm using the strip gauge

provided on the side of the terminal block.

2. Insert the cable into the terminal block.

• Solid cable

Fully Insert the cable into the hole in the terminal
block.

• Twisted cable

Press the lock switch on the terminal block, and
fully insert the cable. Then, release the switch with
the cable inserted.

When removing the cable, pull it out of the terminal
block while pressing the lock switch. 

Note :

Do not press the lock switch extremely strong.

3. After connection completion, bundle cables

together using the cable clip, then fix the clip with
a screw.

If cables are too thick to be bundled together,
replace the cable clip with the supplied clip. 

7.4. Error Message Indication 

When error messages are displayed on the screen after connection and setting completion, the following
causes can be considered. Check the connections and settings again. 

9 mm

Strip gauge

Lock switch

Cable clip

Note

Do not tighten the clip 
extremely strong.

P o l

i n g

E r r o r

l

RM -

U S

E r r o r

B

Error Message Indication

1. Bus line disconnection between the main rack and RM-1200
2. Reversed bus line polarity between the main rack and RM-1200
3. Connected RM-1200 numbers are set for "0" at the main rack.

1. Wrong address setting at the RM-1200
2. Wrong setting of connected RM-1200 numbers at the main rack.

Possible Cause

Summary of Contents for RM-1200

Page 1: ...STRUCTION MANUAL REMOTE MICROPHONE RM 1200 Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference ...

Page 2: ...tions 11 7 2 Connection of the RM 1200 to the Rack Mounted Emergency PA System FS 971 Series 11 7 3 Connection of the RM 1200 s Push in Terminal Block 12 7 4 Error Message Indication 12 8 INITIAL SETTING 8 1 Initial Setup 13 8 2 Address 13 8 3 Usable Group Numbers 14 8 4 Individual Zone Broadcast 14 8 5 Chime Tone Type 14 8 6 Auto Chime Function 15 8 7 Set Data Registration 15 8 8 Termination of t...

Page 3: ...e Doing so may result in the unit falling down and causing personal injury and or property damage Install the unit only in a location that can structurally support the weight of the unit and the mounting bracket Doing otherwise may result in the unit falling down and causing personal injury and or property damage To prevent the electromagnetic wave from badly influencing medical equipment avoid in...

Page 4: ...lt in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Do not stand on nor hang down from the unit as this may cause it to fall down or drop resulting in personal injury and or property damage Cut off the power supply 24 VDC to the unit for safety purposes when cleaning or leaving the unit unused for 10 days or more A fire may result ...

Page 5: ...deck or CD player Internal compressor circuit prevents sound distortion due to large input Functional only when the microphone is used Can be mounted on a wall 4 HANDLING PRECAUTIONS Use the unit only with the voltage specified on the junction panel to which the unit is connected Using a voltage higher than that which is specified may result in equipment failure To clean wipe with a dry soft cloth...

Page 6: ...ted in the initial setting Refer to p 14 6 Group A B selector key Selects either Group A A1 A0 or Group B B1 B0 when making group broadcast Note If the number of groups is set for 10 in the initial setting only Group A can be selected 7 Registration key Registers the line number broadcast zone selected with the numerical key to make broadcast to individual zones 8 Individual zone mode selector key...

Page 7: ... 15 AUX input jack 20 dBV 100 kΩ Connect a cassette deck or CD player Note microphones cannot be connected 16 Chime volume control Adjusts the chime volume Refer to the section 9 VOLUME LEVEL ADJUSTMENT on p 16 17 AUX input volume control Adjusts the AUX input volume Refer to the section 9 VOLUME LEVEL ADJUSTMENT on p 16 18 Microphone volume control Adjusts the microphone volume Refer to the secti...

Page 8: ...ime 1 4 in the initial setting a chime is automatically sounded whenever the TALK key is turned on and off When the unit is set for Auto chime 0 in the initial setting press the CHIME key before and after announcement if it is desirable to sound a chime The In use indicator flashes during internal chime play For initial settings refer to p 13 6 1 All zone Broadcast 1 2 3 Press the ALL ZONE key To ...

Page 9: ...7 A If the 3 and 7 keys are pressed continuously this message appears I n s e u B B 2 3 B If the 2 and 3 keys are pressed continuously this message appears I n s e u A A 1 3 A 7 A I n s e u B A 1 3 A 7 A I n s e u B A 1 3 A 7 B 2 B 3 A Simultaneous broadcast to both groups A and B 1 Press the 1 0 numerical key to select the desired broadcast group 1 0 of A 2 Press the A B group selector key and co...

Page 10: ...ber To cancel the key entry press the RESET key and confirm that the indication 000 is displayed Press the REGISTRATION key When selecting multiple speaker lines repeat Steps 2 and 3 Example Pressing 1 Registration 8 Registration 1 2 Registration displays the following indication Speak into the microphone while the TALK key is pressed The In use indicator lights Press the RESET key to terminate th...

Page 11: ...e Rack Mounted Emergency PA System FS 971 Series Connect the remote control unit to the Junction Panel JP 0410 in the main rack Up to eight remote control units can be connected per junction panel H C 24V GND 1 E H C JP 0410 front panel middle row terminal block GND GND GND GND GND GND 24 V CHIME ACTI GEM RM PWR 1 1 2 2 3 4 5 6 7 8 1 9 10 11 12 IN USE REMOTE REMOTE TIMER GEN RM BUS PWR FAIL CTRL A...

Page 12: ...r using the cable clip then fix the clip with a screw If cables are too thick to be bundled together replace the cable clip with the supplied clip 7 4 Error Message Indication When error messages are displayed on the screen after connection and setting completion the following causes can be considered Check the connections and settings again 9 mm Strip gauge Lock switch Cable clip Note Do not tigh...

Page 13: ...y produces factory preset data and displays the message Store refer to p 15 8 7 Set Data Registration on the screen 8 2 Address Be sure to set the address for 0 when using only one RM 1200 unit Up to eight RM 1200 units can be connected Assign the address of 0 7 consecutively to each unit starting from 0 Take care not to assign the same address to two or more units Using the numerical key set the ...

Page 14: ...8 5 Chime Tone Type Using the 1 5 keys select the chime tone type to be played 1 4 tone chime 2 Two tone chime 3 Single tone chime 4 Gong 5 External chime Note The external chime refers to a chime component installed in equipment connected to the RM 1200 Selecting 5 External Chime disables the Auto Chime Function Pressing the REGISTRATION key stores the selected chime tone type and displays the Au...

Page 15: ...ON key stores the designated Auto Chime mode and displays the message Store 8 7 Set Data Registration To operate the unit exactly as set in Items 8 1 8 6 above select 1 Yes then press the REGISTRATION key The termination message is displayed To change set data press the 2 key to select 2 No then press the REGISTRATION key The display returns to the Initial Setup screen Make changes by following th...

Page 16: ...wise to adjust the volume 4 Sounding a chime turn the chime volume control clockwise to adjust the volume When using external chime unit adjust the volume at the external unit 10 NAME LABEL REMOVAL AND REATTACHMENT 1 Insert a pointed object into the label cover opening and raise the cover to remove it 2 Write broadcast zones in the label When there are ten group broadcast groups use the reverse si...

Page 17: ...rophone 90 degrees reinsert it into the unit then secure it with the screw 3 Install the wall mounting bracket directly on the wall using the supplied wood screws 4 Align holes in the RM 1200 s bottom surface with bracket tabs then slide the unit down into place Microphone Mounting screw Wall mounting bracket Wood screws Wall mounting bracket ...

Page 18: ...rectional electret condenser microphone Speaker Control 20 groups individual speaker line selection up to 330 lines all zone broadcast AUX Input 20 dBV 100 kΩ unbalanced Chime Internal chime FM sound source 4 different tone types Volume Control Microphone AUX input Chime volume controls Connection Cable Twin shielded cable twisted paired cable power cable Maximum Cable Length 800 m Line Resistance...

Page 19: ......

Page 20: ...133 12 589 4B URL http www toa jp ...

Reviews: