When Installing the Unit

• Avoid touching the speaker's sharp metal edge to

prevent injury.

• To avoid electric shocks, be sure to switch off the

amplifier's power when connecting speakers.

When the Unit is in Use 

• Do not operate the speaker for an extended period

of time with the sound distorting. Doing so may
cause the speaker to heat, resulting in a fire.

• Do not stand or sit on, nor hang down from the

speaker as this may cause it to fall down or drop,
resulting in personal injury and/or property
damage.

• Have the speaker checked periodically by the shop

from where it was purchased. Failure to do so may
result in corrosion or damage to the speaker or the
mounts that could cause it to fall, possibly causing
personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

CAUTION

2. GENERAL DESCRIPTION AND FEATURES

TOA's SC-615BS Paging horn speaker features an aluminum horn flare and stainless steel bracket for all-
weather durability. The TOA's unique oval shape horn enhances excellent speech clarity. Other feature
includes a newly developed diaphragm employing special heat-resistant polyimide film to prevent the
diaphragm from absorbing moisture and deformation. High speaker efficiency has also been realized by
minimizing the gap produced when the diaphragm bobbin is installed in the magnetic circuitry slit. The SC-
615BS is certified to the European Standard EN 54-24: 2008 and the International Standard ISO 7240-24:
2010, and is compliant with the British Standard BS 5839-8: 2008.

• Compact, highly intelligible speaker suited to public address announcement applications.
• Stainless steel bracket and hardware (screws, bolts), and powder-coated horn ensure superb

weatherproofing and corrosion-resistance.

• Shock-resistant aluminum oval horn.
• Certified to EN 54-24, and ISO 7240-24, and compliant with BS 5839-8.
• Equipped with a large steatite terminal block of screw type and thermal fuse.
• Provided with a cable gland on the terminal cover.
• One cable gland can be added, enabling bridge wiring.
• Impedance change available by a rotary switch located inside the terminal cover. 

Summary of Contents for SC-615BS

Page 1: ...7 WIRING DIAGRAM 8 8 FREQUENCY RESPONSE 8 9 SPECIFICATIONS 9 Thank you for purchasing TOA s Paging Horn Speaker Please carefully follow the instructions in this manual to ensure long trouble free use...

Page 2: ...personal injury Avoid installing the speaker near seaside or in locations exposed to corrosive gas The speaker or its parts may be subject to corrosion which might cause it to fall or result in person...

Page 3: ...inless steel bracket for all weather durability The TOA s unique oval shape horn enhances excellent speech clarity Other feature includes a newly developed diaphragm employing special heat resistant p...

Page 4: ...factory preset values LINE VOLTAGE 70V 100V IMP 15W 7 5W 5W 2 5W 1 5W 3W 5W 10W 15W 330 670 OFF 1k 2k 3 3k 4 WIRING The terminal cover is not mounted to the speaker unit when shipped from the factory...

Page 5: ...tep 5 Securely tighten the cable gland Note If loosely tightened water or moisture may get inside the terminal cover Screw Terminal cover 5 Waterproof gasket Screw Cable gland 4 4 2 When Bridge Connec...

Page 6: ...Cable gland Waterproof gasket Nut Terminal cover Step 3 Strip the speaker cable jacket Refer to page 4 Step 1 Step 4 Run one each of speaker cables through the cable gland Terminal cover Speaker cabl...

Page 7: ...pplied screws In this case take care not to pinch the wiring and check that the waterproof gasket is secured into place Note If wiring or the waterproof gasket is pinched between the terminal cover an...

Page 8: ...tching transformer Thermal fuse 84 C or 183 2 F Shown above is the factory default wiring 8 0 25 25 0 98 0 98 141 5 55 36 1 42 126 4 96 172 6 77 130 5 12 229 9 02 104 5 4 11 195 7 68 193 7 6 3 9 0 35...

Page 9: ...One cable gland is factory installed For bridge connection one cable gland can be added Cable Connection Screw terminal Steatite Applicable Cable Size Outer diameter 8 0 12 5 mm Conductor Solid wire o...