14. IF A FAILURE IS DETECTED
14.1. TS-D1000-MU Master Control Unit
Symptom
Cause and Points to Check
Remedy
Cannot switch ON the
power.
Is the power cord or DC plug not
connected?
Correctly connect the power cord
and DC plug supplied with the Master
control unit.
Recording cannot
be made to the USB
memory device or
otherwise recording
stops.
Is USB memory capacity insufficient?
When its capacity is insufficient, the
USB memory device remaining capacity
warning indicator lights and the USB
memory device indicator extinguishes.
Insert a USB memory device that has
sufficient remaining capacity, then
confirm that the USB memory device
indicator lights green before commencing
recording. (See p. 21.)
USB memory failure?
If any failure of the USB memory device
is detected, the USB memory device
indicator extinguishes.
Insert a different USB memory device,
then confirm that the USB memory
device indicator lights green before
commencing recording. (See p. 21.)
Recordings cannot be
made to the internal
memory, or otherwise
recording stops.
Is Remaining internal memory capacity
insufficient?
When recording capacity is insufficient,
the Internal memory remaining capacity
warning indicator lights and the Internal
memory indicator extinguishes.
Delete any files recorded to the internal
memory from the browser to create
sufficient free space, then make a
recording after ensuring that the Internal
memory indicator lights green. (Refer
to the separate Instruction Manual
(Browser Settings)*.)
Internal memory failure?
If any failure of the internal memory is
detected, the Internal memory indicator
extinguishes.
Return the equipment status to the
factory default status from a browser,
then make a recording after ensuring
that the Internal memory indicator lights
green. (Refer to the separate Instruction
Manual (Browser Settings)*.)
Note
All recorded files will be deleted if
a unit’s status is returned to factory
default settings.
No sound output.
Is the external processor correctly
connected?
Sound cannot be output if not correctly
connected.
Correctly connect the external
processor. (See p. 37.)
No sound output from
headphones.
Is headphone volume control properly
adjusted?
Adjust the sound volume to an
appropriate level.
Is headphone plug fully inserted?
Ensure that the headphone plug is fully
inserted and secure.