background image

1. SAFETY INFORMATION

Before installation or use, make sure to carefully read all the instructions in this section for correct
and safe operation.
Make sure to follow all the precautionary instructions in this section, which contain important
warnings and/or cautions regarding safety.
After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions

Safety symbols and message described below are used in this manual to prevent bodily injury and 
property damage which could result from mishandling. Before operating your product, read this manual 
first and understand the safety symbols and messages so you are thoroughly aware of the potential 
safety hazards.

When Installing the Unit

• Install the unit only in a location that can

structurally support the weight of the unit and
the mounting bracket. Doing otherwise may
result in the unit falling down and causing
personal injury and/or property damage.

• When installing the unit in the snowy area,

take appropriate measures to prevent snow
from lying on the unit. If the snow lies on the
unit, the unit may fall, causing personal
injuries.

• Do not use other methods than specified to

mount the bracket. Extreme force is applied to
the unit and the unit could fall off, possibly
resulting in personal injuries.

• Attach the safety wire to the unit. If not

attached, the unit could fall off, resulting in
personal injury.

• Use nuts and bolts that are appropriate for the

ceiling's or wall's structure and composition.
Failure to do so may cause the speaker to fall,
resulting in material damage and possible
personal injury.

• Tighten each nut and bolt securely. Ensure

that the bracket has no loose joints after
installation to prevent accidents that could
result in personal injury.

• Do not mount the unit in locations exposed to

constant vibration. The mounting bracket can
be damaged by excessive vibration, potentially
causing the unit to fall, which could result in
personal injury.

When the Unit is in Use

• Should the following irregularity be found

during use, immediately switch off the power,
disconnect the power supply plug from the AC
outlet and contact your nearest TOA dealer.
Make no further attempt to operate the unit in
this condition as this may cause fire or electric
shock.

If you detect smoke or a strange smell

coming from the unit.

If water or any metallic object gets into the

unit

If the unit falls, or the unit case breaks

If the power supply cord is damaged 

(exposure of the core, disconnection, etc.)

If it is malfunctioning (no tone sounds.)

• To prevent a fire or electric shock, never open

nor remove the unit case as there are high
voltage components inside the unit. Refer all
servicing to qualified service personnel.

• To prevent the electromagnetic wave from

badly influencing medical equipment, make
sure to switch off the unit's power when
placing it in close proximity to the medical
equipment.

3

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

CAUTION

WARNING

WARNING

Summary of Contents for UC-4SC615 Q

Page 1: ...INSTALLATION MANUAL IP HORN SPEAKER UC 4SC615 Q Thank you for purchasing TOA s IP Horn Speaker Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment ...

Page 2: ...S 4 NAMES AND FUNCTIONS 5 INSTALLATION PRECAUTIONS 6 INSTALLATION 6 1 How to Use the Cable Gland 6 2 Network Connection 6 3 Terminal Plug Connection 7 SYSTEM SETTINGS 7 1 Before You Begin 7 2 Connection to System Setting 8 INITIALIZATION 9 SOFTWARE LICENSE INFORMATION 10 SPECIFICATIONS ...

Page 3: ...osition Failure to do so may cause the speaker to fall resulting in material damage and possible personal injury Tighten each nut and bolt securely Ensure that the bracket has no loose joints after installation to prevent accidents that could result in personal injury Do not mount the unit in locations exposed to constant vibration The mounting bracket can be damaged by excessive vibration potenti...

Page 4: ... a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communica...

Page 5: ... Multi cast paging can be received from 10 different stations Background music can be selected from the internal audio source play list Can be used by future updates Monitoring Audio stream being monitored by VMS with ONVIF Control Input and Control Output are available 4 NAMES AND FUNCTIONS Bracket Dimensions Rear Panel without Back Cover 1 2 3 4 5 6 7 9 8 5 ...

Page 6: ...iting Yellow Failure or Initialization in progress Extinguished Power OFF 2 Back Cover Covers the connector panel Install the cable after connecting it to the speaker 3 Cable Gland Attaches and secures the end of LAN cable or contact cable Recommended cable φ 4 5 6 0 mm 4 Microphone For picking up ambient sounds or for two way talk 5 LAN Connection Terminal To connect a LAN cable for PoE power sup...

Page 7: ...it In this case use the switching hub which is IEED802 3af compliant When power is supplied from the PoE switching hub be sure to use either PoE PoE IEEE802 3 af at The use of the switching hub other than the specified one may cause a fire 6 3 Terminal Plug Connection Use the removable plugs supplied with the UC 4SC615 unit to connect the terminals by following the instructions below Avoid solderi...

Page 8: ...d Tip Default user name and password are as follows User name uc4sc615 Password uc4sc615guest Step 3 Click Setting icon to open the setting screen 8 Note Use the Google Chrome to open the browser Do not launch multiple web browsers at the same time Step 4 Perform network settings for the UC 4SC615 unit Setting icon Make sure you remember combinations of MAC address and IP address You need a PC for...

Page 9: ...e sure the status indicator changing yellow The initialization has been completed by then Step 2 Open the web browser and enter Unit s IP address in the address field And enter a user name and a password The menu screen is displayed Tip IP address 192 168 14 1 User name uc4sc615 Password uc4sc615guest Reset switch 9 Step 4 Click RESET to restore all the settings to their original states Step 3 Cli...

Page 10: ...T Apache License 2 0 Apache 2 0 Academic Free License version 2 0 AFL 2 0 Eclipse Public License 1 0 EPL 1 0 Freetype Project License FTL Iozone License version 3 ISC License ISC libbzip2 License version 1 0 6 libpng License version 1 2 6 NTP License NTP OpenLDAP Public License version 2 8 OpenSSL License PHP License version 3 01 PHP 3 01 Python Software Foundation License version 2 PSF 2 0 zlib L...

Page 11: ...n voltage 5 V DC short circuit current 2 mA or less removable terminal block 5pins Control Output 1channel relay contact output withstand voltage 30 V DC control current max 300 mA removable terminal block 5pins USB Interface USB2 0 Type A 1port Indicator LAN LINK ACT Yellow Green STATUS Yellow Green Blue Dust Water Protection IP66 Operating Temperature 20 to 55 4 F to 131 F Operating Humidity 90 ...

Page 12: ...ility Information for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representation TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany TOA CANADA CORPORATION ...

Reviews: