background image

6. INSTALLATION

Step 1.

Separate the cable gland components from each 
other.

6.1. How to use the Cable Gland

Follow the instructions below when installing the LAN cable.
*Recommended cable: 

φ

”4.5~6.0”mm

Step 2.

Pass through RJ-45 connector and caulk cable.

Step 3.

Fix all the components except for the lid.

Step 4.

Close the lid.

6.2. Network Connection

From PoE/PoE+ switching hub

The US-4SC615 automatically recognizes the 
network types(10 BASE-T or 100 BASE-TX) and 
start a network connection. For this connection, 
use a straight UTP Category 5 or greater LAN 
(Ethernet) cable terminated with an RJ-45 
connector.

Power can be supplied from the PoE / PoE+ 
switching hub when this terminal is connected to 
it.
In this case, use the switching hub, which is  
“IEED802.3af compliant”.

When power is supplied from the PoE switching hub, be 
sure to use either PoE/PoE+ (IEEE802.3 af/at).
The use of the switching hub other than the specified one 
may cause a fire.

6.3. Terminal Plug Connection

Use the removable plugs supplied with the UC-4SC615 unit to connect the terminals by following the 
instructions below

Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and 
the solder is crushed, possibly resulting in an excessive rise in joint temperatures. 

[ Recommended Cable ]
SOLID WIRE: 24-16 AWG / 0.51-1.29mm
STRANDED WIRE: 24-16 AWG / 0.205-1.31 mm²
WIRE STRIP LENGTH:   6-8mm

[ CTRL IN ]   No-voltage make contact input
Open-circuit voltage: 12 V DC or less
Short-circuit current: 2 mA or less

[ CTRL OUT ]   Relay contact output
Withstand voltage: 40 V DC
Control current: 2 to 300 mA

7

CAUTION

Summary of Contents for UC-4SC615 Q

Page 1: ...INSTALLATION MANUAL IP HORN SPEAKER UC 4SC615 Q Thank you for purchasing TOA s IP Horn Speaker Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment ...

Page 2: ...S 4 NAMES AND FUNCTIONS 5 INSTALLATION PRECAUTIONS 6 INSTALLATION 6 1 How to Use the Cable Gland 6 2 Network Connection 6 3 Terminal Plug Connection 7 SYSTEM SETTINGS 7 1 Before You Begin 7 2 Connection to System Setting 8 INITIALIZATION 9 SOFTWARE LICENSE INFORMATION 10 SPECIFICATIONS ...

Page 3: ...osition Failure to do so may cause the speaker to fall resulting in material damage and possible personal injury Tighten each nut and bolt securely Ensure that the bracket has no loose joints after installation to prevent accidents that could result in personal injury Do not mount the unit in locations exposed to constant vibration The mounting bracket can be damaged by excessive vibration potenti...

Page 4: ... a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communica...

Page 5: ... Multi cast paging can be received from 10 different stations Background music can be selected from the internal audio source play list Can be used by future updates Monitoring Audio stream being monitored by VMS with ONVIF Control Input and Control Output are available 4 NAMES AND FUNCTIONS Bracket Dimensions Rear Panel without Back Cover 1 2 3 4 5 6 7 9 8 5 ...

Page 6: ...iting Yellow Failure or Initialization in progress Extinguished Power OFF 2 Back Cover Covers the connector panel Install the cable after connecting it to the speaker 3 Cable Gland Attaches and secures the end of LAN cable or contact cable Recommended cable φ 4 5 6 0 mm 4 Microphone For picking up ambient sounds or for two way talk 5 LAN Connection Terminal To connect a LAN cable for PoE power sup...

Page 7: ...it In this case use the switching hub which is IEED802 3af compliant When power is supplied from the PoE switching hub be sure to use either PoE PoE IEEE802 3 af at The use of the switching hub other than the specified one may cause a fire 6 3 Terminal Plug Connection Use the removable plugs supplied with the UC 4SC615 unit to connect the terminals by following the instructions below Avoid solderi...

Page 8: ...d Tip Default user name and password are as follows User name uc4sc615 Password uc4sc615guest Step 3 Click Setting icon to open the setting screen 8 Note Use the Google Chrome to open the browser Do not launch multiple web browsers at the same time Step 4 Perform network settings for the UC 4SC615 unit Setting icon Make sure you remember combinations of MAC address and IP address You need a PC for...

Page 9: ...e sure the status indicator changing yellow The initialization has been completed by then Step 2 Open the web browser and enter Unit s IP address in the address field And enter a user name and a password The menu screen is displayed Tip IP address 192 168 14 1 User name uc4sc615 Password uc4sc615guest Reset switch 9 Step 4 Click RESET to restore all the settings to their original states Step 3 Cli...

Page 10: ...T Apache License 2 0 Apache 2 0 Academic Free License version 2 0 AFL 2 0 Eclipse Public License 1 0 EPL 1 0 Freetype Project License FTL Iozone License version 3 ISC License ISC libbzip2 License version 1 0 6 libpng License version 1 2 6 NTP License NTP OpenLDAP Public License version 2 8 OpenSSL License PHP License version 3 01 PHP 3 01 Python Software Foundation License version 2 PSF 2 0 zlib L...

Page 11: ...n voltage 5 V DC short circuit current 2 mA or less removable terminal block 5pins Control Output 1channel relay contact output withstand voltage 30 V DC control current max 300 mA removable terminal block 5pins USB Interface USB2 0 Type A 1port Indicator LAN LINK ACT Yellow Green STATUS Yellow Green Blue Dust Water Protection IP66 Operating Temperature 20 to 55 4 F to 131 F Operating Humidity 90 ...

Page 12: ...ility Information for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representation TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany TOA CANADA CORPORATION ...

Reviews: