This equipment is designed to hold food at a constant temperature, and supply humidity for proofing 

when the application applies, this is NOT a cooking appliance.  This unit is sold for commercial use only 
by personnel trained and experienced in its operation and is not sold for consumer use in and around the 
home nor for use directly by the general public in food service locations.

Before using your new equipment, read and understand all the instructions & labels associated with the 
unit prior to putting it into operation.  Make sure all people associated with its use understand the units 
operation & safety before they use the unit.

All shipping containers should be checked for freight damage both visible and concealed.  This unit has 

been tested and carefully packaged to insure delivery of your unit in perfect condition.  If equipment is 
received in damaged condition, either apparent or concealed, a claim must be made with the delivering 
carrier.

Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a 
request for inspection of concealed damage must be made with carrier within 15 days.  Be certain to 
retain all contents plus external and internal packaging materials for inspection.  The carrier will make an 
inspection and will supply necessary claim forms.

INSTALLATION

This unit is equipped for the voltage indicated on the nameplate mounted the side of the unit.  They will 

operate on alternating current (AC) only. 

The electrical connection must be made in accordance with local codes or in the absence of local codes 

with NFPA No.70 latest edition (in Canada use: CAS STD. C22.1).  The electrical service is provided by a 

cord and plug.  Each appliance requires a 120 volt grounded supply.  Supply wires must be 14 gauge or  

larger to carry the load for one proofer.  

DO NOT CONNECT TO DIRECT CURRENT (DC).

THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDED) PLUG FOR YOUR 

PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED DIRECTLY INTO A 

PROPERLY GROUNDED 3-PRONG RECEPTACLE.

GENERAL OPERATING PROCEDURES

Proofing

Proofing is one of the most important and delicate stages in baking.  About 50% of the product volume 

is created in the proofer.  Proofing accelerates the fermentation of yeast in a warm moist environment 

causing the dough to rise.  The proofer  humidity should be between medium high and high.  For optimum 
results, rolls should be removed from the hot proofer and transferred to the cold proofer at minimum 
proof.  This will ensure that they can be held for 40 minutes without becoming over-proofed.

CAUTION

WARNING

Summary of Contents for 9451-HP12

Page 1: ...HEATER PROOFERS MODEL 9451 HP12 E9451 HP12 9451 HP34 E9451 HP34 Installation and Operation Instructions 2M Z15782 Rev B March 3 2014 E9451 HP12CD IL2427...

Page 2: ...urate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks...

Page 3: ...into place on the floor of the cabinet An electrical socket on the back of the drawer is provided to accept the supplied power cord which is plugged into the drawer through an access hole in the back...

Page 4: ...all contents plus external and internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms INSTALLATION This unit is equipped for the voltage...

Page 5: ...ent off While in proof mode the unit will operate at a lower termperature Allow 45 minutes to pre heat in both heat proof cycle Troubleshooting CAUTION Before disassembling unit electrical power must...

Page 6: ...2M Z15782 Toastmaster Heater Proofer 9451 HP Series SK2574 Rev 3 19 2012 Model E9451 Heater Proofer See Detail A 1 2 4 6 5 7 8 9 10 3...

Page 7: ...2M Z15782 Toastmaster Heater Proofer 9451 HP Series SK2575 Rev A 7 3 2012 Detail A Model E9451 Heater Proofer 12 13 29 30 35 28 27 31 32 33 34 36 17 14 15 16 12 18 19 20 21 7 17 23 17 26 24 25 22 11...