SECTION 1 - DESCRIPTION
4
Griddle Electrical Specification Chart
Voltage
Total
Loading kW/Phase
Nominal Amps/Line Wire
Minimum
Breaker
Supply Wire
Rating*
(AWG) Gauge*
kW
3 Ph
3 Ph
1 Ph
3 Ph
1 Ph
3 Ph
1 Ph
X-Y
Y-Z
X-Z
X
Y
Z
AM24
208
6.2
3.1
3.1
--
15.0
26.0
15.0
30.0
10
8
25
30
240
6.2
3.1
3.1
--
13.0
22.5
13.0
26.0
10
10
30
30
AM36
208
9.3
3.1
3.1
3.1
26.0
26.0
26.0
45.0
10
6
25
40
240
9.3
3.1
3.1
3.1
22.5
22.5
22.5
39.0
10
8
30
45
AM48
208
12.5
6.2
3.1
3.1
39.7
39.7
26.0
60.1
8
4
35
50
240
12.5
6.2
3.1
3.1
35.9
35.9
22.5
52.0
8
6
40
60
* Provided for reference only. Consult national or local electrical codes.
Summary of Contents for ACCU-MISER AM24
Page 6: ...SECTION 1 DESCRIPTION 2 Component Location Figure 1 2...
Page 9: ...SECTION 1 DESCRIPTION 5 Griddle Dimension Drawing...
Page 10: ...SECTION 1 DESCRIPTION 6 NOTES...
Page 16: ...SECTION 2 INSTALLATION 12 NOTES...
Page 23: ...SECTION 4 PARTS LIST 19 SECTION 4 PARTS LIST...
Page 24: ...SECTION 4 PARTS LIST 20 Figure 4 1 Overall Exploded Drawing...
Page 26: ...SECTION 4 PARTS LIST 22 NOTES...
Page 27: ...SECTION 5 SCHEMATICS 23 SECTION 5 SCHEMATICS...
Page 28: ...SECTION 5 SCHEMATICS 24...
Page 29: ...SECTION 5 SCHEMATICS 25...
Page 30: ...SECTION 5 SCHEMATICS 26...
Page 31: ...SECTION 5 SCHEMATICS 27...
Page 32: ...SECTION 5 SCHEMATICS 28...
Page 33: ...SECTION 5 SCHEMATICS 29...