1.4 Creating/selecting a participant

Before

 

you

 

start

 

a

 

recording,

 

you

 

create

 

or

 

select

 

the

 

participant

 

as

 

outlined

 

below.

 

You

 

find

 

more

 

details

 

in

 

the

 

Tobii

 

Pro

 

Glasses

 

2

 

user

 

manual

,

 

section

 

7.2.2.

1.

Make sure the correct study is open in Controller.

2.

Open the Dashboard via the Menu bar.

3.

Check that the Control Panel of the recording unit displays "Ready".

4.

Tap Start New Recording on the Control Panel.

If you use multiple pairs of Glasses 2, check that the correct recording unit is selected.

5.

Create a new participant or select an existing participant.

a.

Create a new participant by entering the participant’s name in the participant field and the participant details in the
participant info field. Tap Create.

b.

Select an existing participant by tapping Existing Participant. Select the appropriate participant from the list.

1.5 Calibrating the participant

The

 

calibration

 

is

 

also

 

outlined

 

in

 

the

 

Tobii

 

Pro

 

Glasses

 

2

 

user

 

manual

,

 

sections

 

7.5.1.2

 

and

 

7.1.5.3.

You

 

ensure

 

that

 

you

 

collect

 

accurate

 

eye

 

tracking

 

data

 

by

 

calibrating

 

your

 

Pro

 

Glasses

 

2

 

individually

 

for

 

each

 

participant.

 

During

 

calibration,

 

the

 

participant

 

must

 

wear

 

the

 

head

 

unit

 

while

 

focusing

 

on

 

the

 

center

 

of

 

the

 

calibration

 

target.

 

The

 

calibration

 

target

 

is

 

printed

 

on

 

the

 

supplied

 

calibration

 

cards

 

and

 

calibration

 

stickers,

 

and

 

in

 

Appendix

 

D

 

of

 

the

 

Tobii

 

Pro

 

Glasses

 

2

 

user

 

manual

.

You cannot reuse the calibration for a participant.

1.

Find the right spot for calibration (avoid light interference and sun exposure).

2.

Adjust the position of the Pro Glasses 2 and determine the right

nose pad

for the participant.

3.

Position the calibration target about one meter from the participant, for example in front of a white wall. Don’t position
the target in front of a screen or the Live View.

4.

Check that the participant looks at the center of the calibration target and that the calibration target appears in the scene
camera live view video in Controller.

5.

When the participant looks at the calibration target, tap the Calibrate icon in the bottom right hand corner of the live view
window. Animated graphics illustrate the progress of the calibration.

6.

After successfully calibrating your participant, always verify the calibration.

a.

Instruct the participant to look at a few objects suggested by you, for example the calibration target or the numbers
on a clock.

b.

Use the live view video to verify that eye tracking data is sufficiently accurate for your study.

7.

If eye tracking accuracy is acceptable, proceed to the next step. If not, tap Recalibrate and repeat the calibration
process.

You can use the

eye images

to position the Pro Glasses 2 correctly on your participant. Details on how to interpret the eye im-

ages can be found

here

.

4

1 Tobii Pro Glasses 2: best practices

Tobii Pro Glasses 2 Best Practices Guide v.1.0.2 - en-US

Summary of Contents for Glasses 2

Page 1: ...Tobii Pro Glasses 2 Best Practices Guide A collection of tips and shortcuts...

Page 2: ...im to these trademarks While every precaution has been taken in the preparation of this document the publisher and the author assume no re sponsibility for errors or omissions or for damages resulting...

Page 3: ...oller via WLAN 3 1 3 2 Connecting Pro Glasses 2 to Controller with an Ethernet cable 3 1 3 3 Basic trouble shooting 3 1 4 Creating selecting a participant 4 1 5 Calibrating the participant 4 1 6 Makin...

Page 4: ...documents on Tobii Pro s website You get the most out of this guide by opening it on a device with internet access That way you will be able to access the additional information provided by the links...

Page 5: ...cording unit s batteries are fully charged 4 2V Check battery levels between recordings to make sure you can finish the whole recording Don t confuse the battery levels of your Pro Glasses 2 and your...

Page 6: ...k of the recording unit d Secure a proper connection by setting the WLAN adapter settings on the computer to obtain an IP address automatically e Make sure that you always connect automatically to the...

Page 7: ...in Appendix D of the Tobii Pro Glasses 2 user manual You cannot reuse the calibration for a participant 1 Find the right spot for calibration avoid light interference and sun exposure 2 Adjust the pos...

Page 8: ...iewer 1 Check that the Live View video is playing this indicates a valid connection between Pro Glasses 2 and Controller 2 Tap the Stop button A confirmation dialog appears 3 Confirm by tapping Yes 4...

Page 9: ...r button for more than four seconds A longer press initiates a hard reboot during which files can get lost or corrupted 1 8 A few bumps on the road If you experience problems while recording with your...

Reviews: