14
Tofino Xenon Security Appliance Tofino SA
Release 04 05/2015
Use of EAGLE One and TOFINOXE Series devices
according to the European Directive 94/9/EC
For
Use in explosive atmospher
es according to the Eur
opean dir
ective 94/9/EC:
Applied Standards:
The Use in Hazardous Locations with explosive atmospher
es is only allowed for
EAGLE One or
T
OFINOXE model No´s. which ar
e labeled accordingly - including ”
II 3 G”,
”Ex nA
IIC
T4 Gc” ”DEKRA
13A
TEX0184X”.
EN 60079-0, 2012 +
A1
1 2013
EN 60079-15, 2010
SPECIAL
CONDITIONS FOR SAFE USE:
•
The modules shall be installed in a suitable enclosur
e pr
oviding a degr
ee of pr
otection of at
least IP54 according to EN 60529, taking into account the envir
omental conditions under
which the equipment will be used.
•
Pr
ovisions shall be made to pr
event the rated voltage fr
om being exceeded by transient
disturbances of mor
e than 1
19
V
.
•
When the temperatur
e under
rated conditions exceeds 70°C at the cable or
conduit entry
SRLQWRU
&DWWKHEUDQFKLQJSRLQWRIWKHFRQGXFWRUVWKHWH
PSHUDWXU
HVSHFL¿FDWLRQRIWKH
selected cable shall be in compliance with the actual measur
ed temperatur
e values.
Manufactured in 72654 Neckartenzlingen / Germany by Hirschmann Automation and
Control GmbH.
DOM: ww/yy (Date of manufactur w - week, y - year. Refer to the device label).