PLS-601 User's Manual
Document #11696 Page - 28
4.2.7 TEACH Function - Continued
ENTERING CHANNEL LOBES
After the channel has been selected, the LOBE data may be entered. If no lobes have previously
been programmed for the selected channel, the 'F' and 'T' fields will display blank characters ('_').
If one or more LOBES already exist for the selected channel, the data for the first LOBE will be
displayed in the 'F' and 'T' fields.
NEW CHANNEL LOBE ENTRY
Display:
CH A01
F
_ _ _ -T_ _ _
(Highlighted character indicates blinking character that can be changed)
Select:
<
CURSOR
Moves the cursor between F and T fields.
New Display:
CHA01 F 1 2 3 -
T
3 4 5
Select:
ENTER
The displayed FROM and TO data fields are entered into
memory. The cursor is set to the ‘-‘ position between the
FROM and TO fields and the data is now considered as
existing data.
New Display:
CHA01 F 1 2 3
-
T 3 4 5
Select:
NEXT
Selects and displays the next LOBE in sequence.
New Display:
CHA02 F _ _ _ - T_ _ _
The '_' in the FROM and TO fields indicates that no
LOBE data has been stored for this LOBE. If numerical
data is present within the FROM and TO fields, than data
has been previously entered for the LOBE that is
displayed.
Select:
FUNCTION:
Terminates the TEACH function and returns the user to
FUNCTION select mode where any one of the PLS-601
functions can be selected.