6(8)
2.2 Settings:
The electronic unit comes with the basic setting allowing the 230v socket to be used despite a
water leak alarm. This means that the product can be safely installed with a fridge or freezer
without risk. Dishwashers and washing machines are built to function without a water supply,
even when they are in operation.
When the electronic unit is plugged into a 230v socket, it will start up and flash GREEN if the
electricity will remain on after a water alarm. It will flash RED if the electricity will be turned off
in the event of a water leak.
To change the setting:
- Press the buttons ON/OFF and TEST/RESET simultaneously for three seconds.
- There will be a beep and the new setting is indicated by a flashing GREEN or RED light.
(Green = 230v ON after a water alarm. Red = 230v OFF after a water alarm)
- All done!
3 Technical Specifications
EL
VHP
230 V / 3680W
DN15 alt. DN20
1–2 water sensors
1 -2 motorised ball valve with
manual override