TOMARK, s.r.o.
Airplane Maintenance Manual
Chapter 05 Inspection and Maintenance
Page 28
Issue: 04.APR 2016
05
Inspection and Maintenance
05-00
General
This chapter contains charts, tables and checklists for time limits,
scheduled and unscheduled maintenance, to enable licensed
personnel to carry out correct inspections on the Viper SD-4 RTC
aircraft. The periodic inspections and checks described and the
related intervals are minimum required for maintaining the aircraft in
airworthy condition.
Specific operation and specific operation environments might require
shortening the intervals.
The regulating airworthiness authority must approve any increase of
interval time.
NOTE
The regulatory authority might require specific (additional) inspection
or calibration items as well as replacement/overhaul intervals not
described in this manual. It is the responsibility of the operator and
maintenance personnel to adhere to national regulations.
05-10
Time Limits and Inspection Program
The Viper SD-4 RTC aircraft scheduled inspection and maintenance
program comprises:
Non repetitive aircraft inspection at 25 hours after delivery of the
aircraft or installation of a new, rebuilt or overhauled engine,
including a break-in inspection and maintenance of the power plant
corresponding to the 100 hours/annual inspection.
Recommended repetitive 50 hour inspection mainly covering power
plant, and fuel system (firewall forward).
Mandatory repetitive 100 hour inspection or annual inspection,
whichever comes first, which includes the coverage of the 50 hour
inspection plus the inspection of the aircraft controls, structure
landing gear and the fuel system aft of firewall.