Scheduled Inspection
(50 h)
100 h/
annual
as
specified
Inspect battery isolation provisions.
○
○
○
1
Cabin Heat System
Inspect hoses for attachment, leaks and wear.
○
○
Inspect air scoop at radiator for cleanness
○
○
Inspect save closure of cabin air nozzles and vents
○
○
Inspect heat exchanger on exhaust for cracks
○
○
Engine Mount
Inspect engine mount attaching bolts at the firewall. Check
torque on all attachment points, re-torque as required.
○
○
○
1
Inspect shock mount rubber elements (vibration isolators) for
condition.
○
○
○
1
Check engine to shock mount attaching bolts, castle nuts and
cotter pins.
○
○
○
1
Inspect engine mount structure for cracks and damage.
Pay specific attention to weld connections. In case of doubt
consider dye penetrant inspection.
○
○
Visually check the firewall for cracks and corrosion, in
particular in the places of all the engine mount attachment
points.
○
Unscrew and visually check the condition of the bolts
attaching the engine to the engine mount.
1000h
Perform Major engine mount inspection per
04-30-20.
2000h
Propeller
Remove spinner.
○
○
○
1
Inspect spinner for cracks and fractures.
○
○
Inspect propeller mounting bolts. Re-torque mounting bolts.
○
○
○
1
1
First 25 hours of operation for new or overhauled engine