TOMARK, s.r.o.
Airplane Maintenance Manual
Chapter 27 Flight Controls
Issue: 11.AUG 2016
Page 109
▶
Disconnect elevator control transmission from elevator crank arm (3
bolts).
▶
Support the elevator.
▶
Note positions of bolt sides and washers.
▶
Catch bushings in between the round flanges of elevator crank arm
when pulling the 3 bolts in the next step.
▶
Remove 3 bolts with castle nuts (including central bolt).
▶
Remove elevator.
Installation
▶
Install in reverse sequence of removal.
▶
Check elevator for free movement.
▶
Check function of elevator trim (RH elevator only), from both control
sticks.
▶
Main switch OFF
27-30-02 Elevator Trim
The control of the elevator’s trim tab is provided by electric servo
operated by trim buttons, located on both control sticks. The
elevator’s trim tab position is indicated on both Dynon Skyview
instruments within the EMS panel.
Issue: 15.FEB 2017