12
ISLAND MODEL INSTALLATION
1)Position the hanging plate on
theceiling and then mark the position of
the screw holes.The hanging plate
should be securely fixed to the ceiling,
11 x ST6 (40 mm)screws for
wooden ceiling
8 x expansion bolts for cement
ceiling
2) Fix the angle bars to the hanging
plate, using the 8 x M5 screws.
3) Extend the angle bars to the
required height and then fix them in
position using the 16 x M5 screws and
nuts with metal washers.
IMPORTANT: The angle bars
must have an overlap of AT LEAST
100 mm.
4) If your cooker hood is going to be
used inextraction mode, then you
should connect the ducting hose to the
ceiling adaptor at this point.
Fix the upper chimney section to the
hangingplate, using the 4 x self tapping
screws.
Slide the lower chimney section onto
the angle bars and raise it until it sits
just below the upper chimney section.