Troubleshooting
MERGE 10-13
Chapter 10
Check Procedure 12-- High mount stop lamp
Please refer to Chapter 1 “Protection for Electrical Safety”.
With Tow/Run switch on RUN and key switch ON, check the high mount stop lamp interface on main
cable with a multimeter set at 200V DC (connect the red probe to green/yellow wire and connect the
black probe to black wire) while depressing the brake pedal. The voltage should be 12V. Perform the
following checks if the voltage is 0:
1. Check whether the DC converter outputs a 12V voltage. Check the converter for failure and replace
it if necessary. Continue with Step 2 if it is ok.
2. Check the fuse in the fuse box and replace it if necessary. If the fuse is ok, go to Step 3.
3. Check the brake switch for normal operation.
4. If everything is ok and the measured voltage is still 0, replace the main cable.
Check Procedure 13 - wiper
Please refer to Chapter 1 “Protection for Electrical Safety”.
With Tow/Run switch on RUN and key switch ON, check the wire connected to the wiper of main cable
with a multimeter set at 200V DC (connect the red probe to yellow/blue wire and connect the black probe
to black wire). The voltage should be 12V. Perform the following checks if the voltage is 0:
1. Check whether the DC converter outputs a 12V voltage. Check the converter for failure and replace
it if necessary. Continue with Step 2 if it is ok.
2. Check the fuse in the fuse box and replace it if necessary. If the fuse is ok, go to Step 3.
3. If no problem is found in the above Step 1 and 2 and there is no 12V output, replace the wiper
harness.
4. If the above checks are satisfactory (ie. there is a 12V output), connect the wiper interface to the
main cable and turn on the wiper switch to check the wiper for normal operation, replace the wiper if
it does not operate.
Check Procedure 14— flashing light
Please refer to Chapter 1 “Protection for Electrical Safety”.
With Tow/Run switch on RUN and key switch ON, check the wire connected to the flashing light of main
cable with a multimeter set at 200V DC (connect the red probe to yellow/blue wire and connect the black
probe to black wire). The voltage should be 12V. Perform the following checks if the voltage is 0:
1. Check whether the DC converter outputs a 12V voltage. Check the converter for failure and replace
it if necessary. Continue with Step 2 if it is ok.
2. Check the fuse in the fuse box and replace it if necessary. If the fuse is ok, go to Step 3.
Summary of Contents for 2010 E-Merge
Page 2: ......
Page 79: ...Electric Component MERGE 9 7 Chapter 9 Control circuit ...