P&G CONTROLLER COMMON ERROR CODES
Diagnostic Code Cause
Correction
1501
Parking brake is released or the parking brake coil
circuit is open
Check to assure the parking brake is not manually
released.
1507
Parking Brake Over Current
Parking brake coil is internally shorted or there is a
problem with the wiring to the brake.
2C00-2C02
Battery voltage is low
Charge the batteries with OEM supplied charger.
2F01
Throttle is depressed during power on or a fault with
the throttle system
Turn the machine off, assure that the throttle
button(s) or throttle pedal are not depressed. Turn
the machine back on and if the condition persists,
seek technical support from your local authorized
RPS distributor.
3101
Brush / Vac Motor - Precharge Fault
This code can be caused by the scrub or vacuum
motor(s) having moisture present or contaminated
with debris.
3102
Traction Motor - Precharge Fault
This code can be caused by the traction motor
having moisture present or being contaminated.
7600
Brush Motor Circuit Open
The controller is not seeing continuity on the brush
motor circuit. This can be caused by the wiring to
the scrub brush motor(s), corroded connections or a
faulty motor.
7601-7603
Brush Motor Circuit Over Current
The brush motor output is exceeding its limit. With
the scrubber turned off, check for entrapped debris
around the brush driver(s) and assure the brushes
turn freely.
7700
Vacuum Motor Circuit Open
The controller is not seeing continuity on the
vacuum motor circuit. This can be caused by the
wiring to the scrub brush motor(s), corroded
connections or a faulty motor.
7701-7703
Vacuum Motor Circuit Over Current
The vacuum motor output is exceeding its limit. This
can be caused by a faulty vacuum motor(s) or
damaged vacuum motor wiring.
1E03
Charger / Seat Switch – Charger is plugged in or
operator is not on the seat of ride on equipment.
On board charger is plugged into the wall outlet. Off
board charger is plugged into charging port. The
switch at the charger plug for an external charger is
out of adjustment. (Operator is not present on seat
GTR and EX machines Prior to Serial Number 100xxx)
7500
LCD Communication Error
The LCD lost communication to the controller. Check
the 6 wire harness between the LCD module and it's
connections.
7801-7802
Traction Motor Over Current
The traction motor output is exceeding its limit.
Check to assure the parking brake is releasing when
the throttle is engaged. Assure all wheels that
contact the floor turn freely.
7804
Boost Mode
The code 7804 indicate the controller is in Boost
Mode and considered normal under hard
acceleration or when climbing a hill.
7900
Emergency Stop Activated
The emergency stop is activated. If the machine is
not equipped with an emergency stop switch
typically the LCD module has failed.
Below are common diagnostic codes and some typical causes / remedies. If the information provided in the "Correction" section does
not cure the code, seek technical support from your local authorized RPS Corporation distributor.
Summary of Contents for CARBON 24'' EDGE
Page 14: ... 14 TC CARBON OP EN 3 3 2 2 1 4 REMOVE SQUEEGEE ...
Page 15: ...TC CARBON OP EN 15 ADJUST SQUEEGEE ...
Page 17: ...TC CARBON OP EN 17 1 2 4 3 5 SPEED TRANSPORTATION FORWARD ...
Page 18: ... 18 TC CARBON OP EN TRANSPORTATION REVERSE 1 2 ...
Page 20: ... 20 TC CARBON OP EN 4 7 2 3 1 5 6 SPEED OPERATION SCRUBBING ...
Page 23: ...TC CARBON OP EN 23 FLUSHING RECOVERY TANK 1 2 ...
Page 24: ... 24 TC CARBON OP EN CLEAN DRAIN SAVER 1 2 3 ...
Page 25: ...TC CARBON OP EN 25 CLEAN CYLINDRICAL HOPPER 2 1 ...
Page 26: ... 26 TC CARBON OP EN CLEAN VAC BOX SYSTEM 1 1 3 4 3 4 2 5 6 7 8 ...
Page 27: ...TC CARBON OP EN 27 REMOVE DISK BRUSHES 1 1 2 Rotate after 25 hrs ...
Page 28: ... 28 TC CARBON OP EN REMOVE CYLINDRICAL BRUSHES 1 2 Rotate after 25 hrs ...
Page 35: ...BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...