background image

parent unit LEDs

charging your monitor before first use:

THE PARENT UNIT:

 

 

The parent unit is supplied with a rechargeable battery pack.  

 

To insert the battery pack, open the battery casing with a screwdriver. Insert the supplied 

 

rechargeable battery pack. Take extra care to ensure that the battery pack is inserted correctly and 

 

the right way round. Refit the battery casing securely with a screwdriver.

 

DO NOT use a non-rechargeable battery pack. ONLY use battery pack supplied. 

 

Plug the mains power cable into socket on side of parent unit and connect the other end of the 

 

mains power cable to the mains power.

 

Power on the parent unit and charge for 10 hours before use.

THE BABY UNIT:

 

The baby unit does not require batteries if powered from the mains. 

 

If mains usage is not available, the baby unit will operate on batteries 4 x alkaline AA (LR6), which are 

 

not supplied.

 

To insert batteries, open the battery casing with a screwdriver. Insert 4 x alkaline AA (LR6) batteries 

 

(rechargeable or non-rechargeable, but not mixed) and close casing securely with screwdriver. Take 

 

extra care to ensure that the batteries are inserted correctly and the right way round. 

 

There is NO charging function on the baby unit.

 

The battery light flashes orange to indicate the battery is low.

 

Battery power is disconnected automatically when the mains adaptor is in use. If the adaptor is turned off 

 

at the mains and still remains connected to the monitor then the batteries will be automatically activated.

1

1

2

3
4

5

2

3

4
5
6

M

3

20°C

3

20°C

correct use of batteries

  Non-rechargeable batteries are not to be recharged.

  Rechargeable batteries are to be removed from the baby unit before being charged.

  Rechargeable batteries are only to be charged under adult supervision.

  Different types of batteries or new and used batteries are not to be mixed.

  Only batteries of the same or equivalent type as recommended are to be used.

  Batteries are to be inserted with the correct polarity.

  Exhausted batteries are to be removed from the monitor.

CAUTION: risk of severe malfunction if battery is replaced by an incorrect type. Dispose of used 

batteries according to the instructions.

SIGNAL STRENGTH

BATTERY

ZOOM

SENSOR PAD

NO MOVEMENT 
ALARM

SPEAKER

TEMPERATURE

FLASH

ON

ON

FLASH

ON

OFF

ON

FLASH

OFF

ON

Signal obtained, but no connection

Signal weak

Signal good

Signal excellent

Signal out of range

Empty and needs to be recharged

Low

Full

Charging

Display when the Sensor Pad is
connected securely and turned ON

Flashes when Sensor Pad is ON but not 
securely connected/disconnected

Show as constant when Sensor Pad is 
connected but switched off at Baby Unit

OFF when Sensor Pad function is OFF 
and not connected

Display when the ALARM is triggered

Flashes if alarmed but then the child 
starts to move again

Indicates volume level when user 
adjusts volume

Degree

Celsius

Fahrenheit

PAD OFF

°

C

F

MAINS POWER

NIGHT LIGHT

ON

On when parent unit is connected with 
AC power adaptor and without battery 
pack installed

Low

Medium

High

3

2

1

CAUTION: 

Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according

to the instructions. Use only rechargeable  Li-polymer battery 950mAh with rating: 3.7/950mAh.

Rechargeable battery: Manufacturer: BYD COMPANY LIMITED Model no.: SCD530-1

FOR REPLACEMENT PARENT UNIT BATTERIES, VISIT OUR WEBSITE www.tommeetippee.com 

Summary of Contents for 1094SB

Page 1: ...mpartment Temperature detector Sensor pad sensitivity switch Press to power on or off LED lights up amber when switched on Low medium high ON when alarm is triggered FLASHES if alarmed but child then starts to move again OFF FLASHES ORANGE when battery is low if using batteries CONSTANT ORANGE when using AC power adapter Takes 4 x AA alkaline batteries not included Remove casing using a screwdrive...

Page 2: ...digital video monitor with movement sensor pad INSTRUCTIONS FOR USE model 1094S tommeetippee com ...

Page 3: ...s to view the previous menu level Press and hold to move back to the monitoring mode directly In zoom mode Press to navigate the zoom panel left In zoom mode Press to navigate the zoom panel right STEADY ORANGE link between parent unit and baby unit is excellent SLOW FLASHING ORANGE link between parent unit and baby unit is good QUICK FLASHING ORANGE link is out of range NO LINK is displayed OFF p...

Page 4: ...not to be recharged Rechargeable batteries are to be removed from the baby unit before being charged Rechargeable batteries are only to be charged under adult supervision Different types of batteries or new and used batteries are not to be mixed Only batteries of the same or equivalent type as recommended are to be used Batteries are to be inserted with the correct polarity Exhausted batteries are...

Page 5: ...OWER INDICATOR is on The baby unit is now powered on and will link with the parent unit Ensure that the sensor pad on off switch is turned OFF Direct the camera towards the baby s cot For adjusting the zoom feature refer to section Adjusting the Zoom testing the parent unit First ensure that the baby unit has been set up and is working correctly following the previous instructions To test the pare...

Page 6: ...ut the Sensor Pad being connected securely there will be an error tone from the Baby Unit and the Sensor Pad icon in the Parent Unit will flash The text PLEASE CONNECT THE SENSOR PAD will also appear on the Parent Unit 6 Test the alarm by continuing to touch the mattress for a few moments and then step away from the cot and stop all movement near the sensor pad 7 After approximately 20 seconds the...

Page 7: ...by makes Level 5 the microphone is always on Fahrenheit or Celsius 52 F 69 F or 11 C 20 C 70 F 86 F or 21 C 30 C LEVEL 1 1 2 3 4 5 1 2 3 4 5 LEVEL 2 LEVEL 3 LEVEL 2 LEVEL 3 adjusting the zoom The zoom mode allows you to view your baby The ZOOM icon will be displayed in the status bar of the parent unit In monitoring mode press ZOOM to enter zoom mode Press UP DOWN LEFT RIGHT to navigate the zoom a...

Page 8: ...CD of the parent unit If volume is OFF before paging starts reset it to default volume level 4 During paging any key pressed on the parent unit will stop the paging tone If the link is lost between the parent unit and the baby unit the paging tone will not be emitted when both UP 9a and DOWN 9b keys are pressed together There will be no change on baby unit If paging is not stopped it will expire i...

Page 9: ...an 1 5 metres The parent unit is too sensitive to room sounds The microphone sensitivity level of the baby unit may be set too high Decrease the microphone sensitivity level of the baby unit from the parent unit The baby monitor system produces a high pitched noise The parent unit and the baby unit are too close to each other Make sure the parent unit and baby unit are at least 1 5 meters away fro...

Page 10: ...conditions as well as spatial and structural factors Up to 25 fps Dynamic Frame Rate Color LCD QVGA 320x240 pixel Use only with class 2 power source DECLARATION OF CONFORMITY We Jackel International Ltd trading as Mayborn Baby and Child Dudley Lane Cramlington Northumberland NE23 7RH UK declare under our responsibility that the electrical product Tommee Tippee Model 1094S Closer to Nature Digital ...

Reviews: