111
1~32
0x10
0x00
0x18
0x00
0x01
0x02
0x00
0x00~0x3B
Calculated based
on the first 9
bytes
3)
Return Instruction Format
6.4.2.24
Address 25 (Timer Minutes)
1)
Commands Description
This command is used to set the value of the timer minutes in manual mode. Instruction data byte 1
ranges from 0 to 59. The command is invalid when the output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data
byte 1
Data byte
2
CRC
Low
CRC
High
1~32
0x10
0x00
0x19
0x00
0x01
0x02
0x00
0x00~0x3B
Calculated based
on the first 9
bytes
3)
Return Instruction Format
6.4.2.25
Address 26 (Timer Hours)
1)
Commands Description
This command is used to set the value of the timer hours in manual mode. Instruction data byte 1 ranges
from 0 to 99. The command is invalid when the output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data
byte 1
Data byte
2
CRC
Low
CRC
High
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x18
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x19
0x00
0x01
Calculated based on the first 6
bytes
Summary of Contents for TH7105