5.2  ABOUT THE STOVE

smoke 

pipe

handle

window 

with outer 

ring
cladding

base

firing 

chamber 

door

firing 

chamber

grate

ash box

5.3.2  VENT PIPE AND VEN-
 

TILATING SYSTEM

Extractor  hoods  and  ventilating  sys-
tems can affect the operation of your 

A

A

A

B

E

F

A

A

A

B

E

F

4.3 GENERAL SAFETY 
 

INSTRUCTIONS

• Never  leave  children  alone  or  unat-

tended at a burning fireplace.

• Teach  your  children  how  to  behave 

properly  and  operate  safely  the  fire-
place.

• Every stove gets hot when fired: risk 

of burning!

• Avoid  touching  the  outside  surfaces 

when the stove is operating.

• Do not burn refuse or painted wood.

• Dispose  of  the  ashes  only  after  they 

have cooled completely.

• Inform  your  specialised  dealer  with-

out delay of defect gaskets.

• Observe the information in our oper-

ating instructions and make a proac-
tive  contribution  to  fire  prevention 
and  the  protection  of  our  environ-
ment.

4.4 CHIMNEY SAFETY 
 

INSTRUCTIONS

The  condition  and  functionality  of 
your  chimneys  must  be  inspected  by 
a  chimney  sweep  or  specialist  before 
the  Tonwerk  storage  heating  stove  is 
installed.

This  will  provide  the  optimal  condi-
tions for trouble-free heating.

4.2 SAFETY DISTANCES TO SWIVELLING TONWERK STORAGE
  

HEATING STOVES: T-EYE

Safety distance A 

 

The side and rear panels must be  no closer 
than 10 cm to flammable materials

Safety distance B 

 

Smoke pipes must be no closer than 20 cm 
to flammable materials

Safety distance C+D 

 

Flammable  floor  materials  must  be 
no  closer  than  50  cm  to  the  front  and 
30 cm to the sides.

Safety distance E 

 

A minimum distance of 80 cm applies to 
the whole swivelling range

Safety distance F 

 

The minimum distance from the ceiling 
is 50 cm

Safety distance A 

 

The side and rear panels must be  no closer 
than 10 cm to flammable materials

Safety distance B 

 

Smoke pipes must be no closer than 20 cm 
to flammable materials

Safety distance C + D 

 

Flammable  floor  materials  must  be 
no closer than 50 cm to the front and 
30 cm to the sides

Safety distance E 

 

Firing  chamber  apertures  must  be  no 
closer than 80 cm to flammable mate-
rials within the radiation zone

Safety distance F 

 

The minimum distance from the ceiling 
is 50 cm

4.1  SAFETY DISTANCES TO FIXED TONWERK STORAGE 
 

HEATING STOVES: T-EYE

4. FIRE PROTECTION

The national and European standards, the local and building legislation, and the 
fire safety terms and conditions must be observed without condition.
Your chimney sweep or Tonwerk partner company will be pleased to inform you.

5. OPERATING INSTRUCTIONS

5.1  BEFORE FIRING THE
 

STOVE FOR THE FIRST

 

TIME

Dear Customer, 

You have now been instructed by one 
of  our  specialised  dealers  on  how 
to  fire  your  Tonwerk  storage  heating 
stove.

In  these  operating  instructions  we 
wish  to  set  down  each  step  that  you 
must  take  if  you  are  to  encounter  no 
problems  when  operating  your  Ton-
werk storage heating stove.

Read through these operating instruc-
tions carefully and keep them in a safe 
place.  Your  specialised  dealer  will  be 
pleased  to  assist  you  with  any  ques-
tions you may have.

5.3.1  WHEN THE STOVEPIPE
 

PAINT DRIES

When the stove is fired for the first few 
times the paint on the stovepipe emits 
an odour when it dries.
Make sure that the combustion cham-
ber  is  completely  filled.  The  Tonwerk 
storage  heating  stove  then  reaches 
its optimal operating temperature and 
the paint dries faster.
Also make sure the room is well venti-
lated during this phase.

5.3  GENERAL INFORMATION

5.3.3   HEATING IN THE 
 

TRANSITION TIME 

 

AND IN DIFFICULT 

 

CONDITIONS

In damp or foggy weather, at outdoor 
temperatures  from  15  °C,  and  during 
the transition time you are advised to 
light a pilot fire before firing the stove 
proper.  This  serves  to  displace  the 
cold, heavy air in the chimney and to 
create the right conditions for the opti-
mal extraction of smoke.

C

D

D

C

D

D

5.3.4  PREPARATIONS FOR 
 

FIRING

Have  ready  an  adequate  supply  of 
chopped firewood, ecofriendly lighting 
aids, and kindling. You are best storing 
the wood in a warm room for a number 
of days before firing.

Tonwerk storage heating stove.
Please  make  sure  that  there  is  ade-
quate incoming air for multiple instal-
lations.

This  pilot  fire  is  lit  with  paper  in  the 
chimney’s inspection aperture until ex-
traction is assured.

6. FIRING THE STOVE

To open –  
push the handle to the back (1) 
To close –  
pull the handle to the front (2)

IMPORTANT

 

The lock must 
engage!

2

1

Design: GAAN Gabriela Vetsch, André Riemens

Summary of Contents for T-EYE

Page 1: ...K SPEICHEROFEN INSTRUCTIONS D UTILISATION DU POELE À ACCUMULATION TONWERK OPERATING INSTRUCTIONS TONWERK STORAGE HEATING STOVES ISTRUZIONI PER L USO DELLA STUFA D ACCUMULO TONWERK Design GAAN Gabriela Vetsch André Riemens T EYE ...

Page 2: ...he Entwicklungen red dot award für hohe Designqualität Designzentrum Nordrhein Westfalen VHe Qualitäts und Gütesiegel für typengeprüfte Speicheröfen Eidgenössischer Preis für Gestaltung Produktdesign Design Plus ISH Frankfurt DISTINCTIONS OBTENUES PAR LES POELES À ACCUMULATION TONWERK Design Preis Schweiz Prix du Design Suisse MUT Umweltpreis Prix de l environnement MUT distinction ac cordée aux d...

Page 3: ...eat with a particularly pleasant feeling It is physiologically beneficial and soothing Since prehistoric times humans have utilised and enjoyed radiated heat It is transmitted by electromagnetic waves in the infrared range Radiated heat travels through air without loss and without heating this Not until it encoun ters solid bodies like walls objects and also people does it generate heat This effec...

Page 4: ...arbon dioxide ashes formed primarily of the wood s mineral constituents and water The combustion process on firewood can be divided roughly into three phases Heating and drying In this first phase the water and other volatile substances stored in the firewood evaporate Pyrolysis In this second phase the firewood decomposes at temperatures from about 150 C Actual combustion In this third phase the ...

Page 5: ...m distance from the ceiling is 50 cm 4 1 SAFETY DISTANCES TO FIXED TONWERK STORAGE HEATING STOVES T EYE 4 FIRE PROTECTION The national and European standards the local and building legislation and the fire safety terms and conditions must be observed without condition Your chimney sweep or Tonwerk partner company will be pleased to inform you 5 OPERATING INSTRUCTIONS 5 1 BEFORE FIRING THE STOVE FO...

Page 6: ...The added wood ignites within a few minutes and burns from bottom to top Roughsurfacesontheoutercladdingcanbevacuumedoffwithanupholsteryattachment Polishedsurfacesarecleaned with a spray wet cloth The provided cleaning stone is used to remove stubborn soiling Under no circumstances must you use hard brushes or chemical cleaning agents The optimal functionality is obtained when the chimney stovepip...

Page 7: ...er questions you may have Garantie zertifikat Wir gewähren für Ihren neuen Tonwerk Speicherofen eine Garantie von 5 Jahren Die Garantielaufzeit beginnt mit dem Tag der Inbetriebnahme durch den Fachhändler Der Garantieanspruch tritt dann in Kraft wenn der Kaufpreis für den Ofen vertragsgemäß en trichtet ist und das Garantiezertifi kat vollständig ausgefüllt innerhalb 30 Tagen an die Tonwerk Lausen ...

Page 8: ...Tonwerk Lausen AG Hauptstrasse 74 CH 4415 Lausen Telefon 41 0 61 927 95 55 Fax 41 0 61 927 95 58 info tonwerk ag com www tonwerk ag com ...

Reviews: