Guidance MP-888 - Supplement to the manual of instructions 

8/10 

 

 

5.  Parameter 

– Overview 

 

 

Function 

Factory adjusted 

User

 

Ag

ent

 

T

O

O

L

-T

E

MP

  Description 

P1 

Maximum 
temperature

 

Setting depends 
on model 

(0.0...400.0°C) 
(32.0...752.0°F)

 

      If the maximum temperature exceeds, 

the heating and cooling are inactive and 
the maximum temperature LED lights up 
on the controller.

 

P2 

Temperature 
deviation control  
(Deviation between 
set and actual 
temperature) 

5.0°C / 9.0°F 

(0…20.0°C) 
(0…36.0°F) 

      The limit determines the maximum 

deviation from the nominal value, which 
is still tolerated. If the actual temperature 
outside the set point window the alarm 
will sound and the Temperature 
deviation control LED lights. If the restart 
lock (P24) is turned on, the temperature 
deviation control is active only when it 
reaches the set temperature. A set point 
changes the start-up lock again. 

P3 

Flow measurement 
function 

0: Manuel 

1: Automatic 

      If the automatic flow measurement is 

enabled, after 20s the measured flow is 
stored and monitoring is enabled. The 
green LED lights up. 

P4 

Alarm value flow 

8.0 L 

(0.1…999.9 L)

 

      (P3) set to manual 

Alarm is triggered when the set value is 
exceeded. 

P20 

Temperature unit 

1: °C 

2: °F

 

      Change the temperature unit: 

When the unit started the selected unit 
will be indicated for a short time.  

P21

 

Temperature sensor 

Setting depends 
on model 

1: Fe-Ko  

2: NiCr-Ni   K 
3: Pt 100 2-Draht 
4: Pt 100 3-Draht 

 

 

 

Selection of temperature sensor 

P22

 

Temperature 
adjustment on Pt 100 

0.7°C

 / 33.3°F 

(0.0...130.0°C) 
(0.0...234.0°F) 

 

 

 

When using very long sensor lines  
(Pt 100) the resistor of the line can be 
compensated. A compare measurement 
is needed. For example:  
measured temperature:  100°C 
indicated temperature:  108°C.  
-> set 8°C (difference)  

P23 

Analog input 

1: Voltage 0-10V 

2: Current 0-20 mA 
3: Current 4-20 mA

 

      Analog input for setpoint selection.  

0-10 V  

(switching threshold <0.1V)

  

0-20 mA 

(switching threshold <0.5mA)

 

4-20 mA 

(switching threshold <0.1mA)

 

P24 

Starting interlock for  
temperature deviation 
control 

0: OFF 

1: ON

 

 

 

 

see P2

 

Summary of Contents for MP-888

Page 1: ...Guidance Supplement to the manual of instructions Microprocessor Temperature Controller MP 888 software version C30 06 2014 Version 14...

Page 2: ...binding obligation on the part of TOOL TEMP AG and are subject to change without notice In case of inconsistencies in the English translation the German version shall prevail Copyright 2013 TOOL TEMP...

Page 3: ...control active LED green Alarm flow control LED red 8 LED Cooling Lights up when the cooling relay is activated 9 LED Heating Lights up when the heating relay is activated 10 LED Sensor failure Light...

Page 4: ...ensor connection 21 23 Temperature sensor note 22 Pt 100 compensation 5 Flow control encoder signal 6 Connection external set point 26 28 Analog input 4 20mA 27 28 Analog input 0 10 V 7 Connection act...

Page 5: ...T 280 2 P 46 P US 46 TT 360 TT 370 TT 380 TT 380 2 TT 380 48 kW P 47 P US 47 TT 300 TT 301 TT 302 TT 303 TT 304 TT 305 TT 500 TT 700 Temperature Control Units with flow control Programme New models Ol...

Page 6: ...0 WK TT 216 000 OT TT 14 000 E LC TT 4 500 TT 5 000 TT 9 500 TT 11 000 TT 11 000 WK TT 12 000 TT 12 000 WK TT 14 000 TT 14 000 WK TT 20 000 TT 23 000 TT 23 000 WK TT 25 000 TT 28 000 TT 28 000 WK TT 2...

Page 7: ...ress button once to save 4 Navigation in the controller Enter into the controller and navigate to the different parameter To enter into the programme of the controller the program button has to be pre...

Page 8: ...1 Automatic If the automatic flow measurement is enabled after 20s the measured flow is stored and monitoring is enabled The green LED lights up P4 Alarm value flow 8 0 L 0 1 999 9 L P3 set to manual...

Page 9: ...ature at 0 V OUTPUT 0 0 C 32 0 F 50 0 399 9 C 58 0 751 8 F Lower scaling point of the voltage analog output 0 V corresponds to 0 C P32 Temperature at 10 V OUTPUT 400 0 C 752 F 49 9 400 0 C 57 8 752 0...

Page 10: ...15s 6 255s Controller time base of PWM outputs Time of the analyse of the control system to define the variable P53 Flow unit 0 Flow OFF 1 Impulse Hz 2 litres min 3 US gallons min 4 Imperial gal min F...

Reviews: