d) Connected Devices

• Make sure any tips connected to the air gun are correctly attached and cannot 

become loose during use.

e) Location

• Place  the  workstation  on  a  clean,  level,  non  flammable  surface  of  a  sufficient 

size. Protect the workstation against vibrations. Do not place the workstation on a 

flammable surface (e.g. rug or tablecloth). Always use a non-flammable, heatproof 

surface. 

• Keep  the  workstation  away  from  flammable  or  combustible  materials  (e.g. 

curtains). 

• Do not place the workstation on valuable furniture without using suitable protection, 

as this may result in scratch marks, pressure points, discolouration or burn marks. 

• Do not use the product in the immediate vicinity of strong magnetic/electromagnetic 

fields, transmitter aerials or HF generators. These may affect the electronic control 

system.

• Make sure that there is enough space in the direction from which the hot air nozzle 

discharges hot air. The hot air may cause a fire if there is not enough space!

• Ensure that there is sufficient lighting.

• Keep your work area clean and tidy. 

f) Risk of Burns

• Never use the workstation to heat up liquids or gases.

• Never point the flow of hot air at the work station, mains cable, hose or other parts. 

In addition, never point the flow of hot air at people or animals, as this may cause 

burn injuries!

• Never touch the tip of the hot air nozzle or soldering iron.

• Do not attempt to remove a tip from the airgun when it is hot.

g) Personal Safety

• Wear suitable protective clothing and safety goggles when soldering/desoldering. 

Splashing “spitting” solder may cause serious burns or eye damage.

• Never work under the influence of alcohol or medication.

• Do  not  ingest  solder.  Do  not  eat  or  drink  during  soldering.  Wash  your  hands 

thoroughly after working with solder.

• Ensure that there is sufficient ventilation while soldering. Vapours can be harmful 

to your health. 

h) Fuse

• A defective fuse must be replaced with a new fuse with the same specifications 

(see “Replacing the fuse”). Do not repair or bridge a defective fuse, as this may 

cause a fire or result in fatal electric shock.

Operating Elements

15 

4

3

2

1

5

6

7

8
9

10

11
12

14

13

1  Hot air gun handle

2  Hot air gun controls

3  Hot air gun holder

4  Hot air gun nozzle

5  Main unit carry handle

6  Soldering iron handle

7  Main power switch  

ON/OFF

8  LCD display:  

SMD REWORK

9  LCD display: 

SOLDERING STATION 

10 Soldering iron holder

11  Soldering iron input 

socket

12 Sponge

13 Fuse holder

14 Power socket

15 Control panel

Connection and Setup

  The power switch should be in the OFF position, and the mains cable should not be 

connected to the power supply. 

 

The hot air gun holder must be attached to the main unit before use.

a) Assembling the Hot Air Gun Holder

•  The holder can be mounted to the left or right side of the main unit:

Left side 

Right side

•  Use 4x screws (included) to attach the mounting plate to the hot air gun holder as shown.

•  Use 2x screws (inlcuded) to attach the mounting plate to the left or right side of the main 

unit.

•  Before connecting to the power supply, check the attachment is secure by placing the hot 

air gun into the holder (3)

b) Soldering Iron

•  Insert the sponge (12) into the tray at the base of the holder (10).

•  Insert the soldering iron into the holder.

•  Attach the soldering iron plug to the input socket (11) on the main unit and then use the 

locking screw to secure the connection.

c) Main Unit Power Supply

•  Make sure the main power switch (7) is in the OFF position.

•  Connect one end of the power cable into the power socket (14), and the other end to a 

mains power supply.

Operation

  Touching or soldering capacitors (or similar components) or leads/cables that are 

connected  to  capacitors  may  cause  a  fatal  electric  shock!  Capacitors  may  stay 

charged for several hours after you switch off the power supply!

a) Main Unit Power ON/OFF

•  Use the main power switch (7) to turn the power ON or OFF.

•  LCD displays (8) and (9) will show “OFF”.

REWORK STATION

SOLDERING STATION

b) Change Temperature Unit (°C and °F)

•  The main power switch should be OFF (7).

•  Press and hold UPDOWNSET, then turn the power switch ON (7).

•  The new temperature unit will show on the LCD displays (8) and (9).

c) Change Hot Air Gun Tips

  Risk of burns! Allow the hot air gun to completely cool before attempting to attach or 

remove any tips from the nozzle (4)!

•  Insert the selected tip over the hot air gun nozzle (4), making sure it is securely attached.

•  Remove the tip by pulling it away from the nozzle (4)

  Tighten or loosen the bolt on the tip if needed.

Summary of Contents for 2108712

Page 1: ...n elektrischen Komponenten oder Bauteilen durch die unter Spannung stehen Trennen Sie solche Komponenten vorher stets von der Stromversorgung Achtung Sollte es einmal vorkommen dass Flüssigkeit in die SMD Lötstation gelangt ist schalten Sie immer zuerst die Netzspannung zur Netzsteckdose ab an der die Lötstation angeschlossen ist Sie müssen den zugehörigen Leitungsschutzschalter abschalten bzw die...

Page 2: ... 7 Hauptschalter ON OFF 8 LC Display SMD REWORK 9 LC Display SOLDERING STATION 10 Lötkolbenhalterung 11 Eingangsbuchse für Lötkolben 12 Schwamm 13 Sicherungshalterung 14 Netzanschluss 15 Bedienfeld Anschluss und Aufstellung Stellen Sie sicher dass sich der Hauptschalter in der OFF Position befindet und das Netzkabel noch nicht an die Stromversorgung angeschlossen ist Die Halterung der Heißluftpist...

Page 3: ...der Halterung 3 befindet und sie schaltet sich aus wenn die Temperatur unter 100 C fällt Das Hauptgerät wechselt dann in den Ruhemodus und auf dem LC Display 8 wird SLP angezeigt SLP Ruhe Standby Modus SET Eingestellte Temperatur REAL Tatsächliche Temperatur b Außerbetriebsetzung Um Schäden am Produkt zu vermeiden lässt sich das Hauptgerät erst dann mit dem Hauptschalter 7 AUSSCHALTEN wenn die Tem...

Page 4: ...n Sie den eingestellten Temperaturwert Schalten Sie die Stromversorgung des Geräts AUS warten Sie 20 Minuten und schalten Sie sie wieder EIN Sollte die Fehlermeldung weiterhin angezeigt werden wenden Sie sich an unseren technischen Kundendienst oder anderes Fachpersonal Pflege und Reinigung a Hauptgerät und Heißluftpistole Beide sind in der Regel wartungsfrei Trennen Sie das Produkt vor der Durchf...

Page 5: ... supply beforehand Caution If liquid does enter the workstation switch off the mains voltage to the socket containing the mains plug switch off at the corresponding circuit breaker or remove the safety fuse and then switch off at the corresponding RCD protective switch You can then unplug the power adapter from the mains socket Discontinue use immediately and take the product to a specialist repai...

Page 6: ... 1 Hot air gun handle 2 Hot air gun controls 3 Hot air gun holder 4 Hot air gun nozzle 5 Main unit carry handle 6 Soldering iron handle 7 Main power switch ON OFF 8 LCD display SMD REWORK 9 LCD display SOLDERING STATION 10 Soldering iron holder 11 Soldering iron input socket 12 Sponge 13 Fuse holder 14 Power socket 15 Control panel Connection and Setup The power switch should be in the OFF positio...

Page 7: ...n 5 seconds to assign a shortcut The temperature will appear on the LCD 9 above the corresponding shortcut button to indicate it has been assigned SMD REWORK STATION a Power On Turn the main power switch ON 7 On the control panel 15 press the left POWER button to activate the SMD REWORK STATION The hot air gun will start heating up when the handle 1 is removed from the holder 3 The hot air gun wil...

Page 8: ...e Disconnect the product from the mains and allow all parts to cool down completely before each cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Clean the product with a dry fibre free cloth b Soldering Iron Always keep the tip tinned before switching off or storing for any period of time Never...