Recall Shortcut

•  Press the left POWER   button to activate the SMD REWORK STATION

•  On the control panel (15) press SET until “REAL” shows on the LCD display (8).

•  Press and hold the left POWER   button followed by a shortcut button (12, or 3) for 

approximately 5 seconds.

•  The LCD display (8) will indicate which shortcut has been recalled “P01/P02/P03” along 

with the actual temperature “REAL”. 

P01

P02

P03

f) Temperature Compensation/Calibration 

•  Press and hold the left POWER   button and the   button on the hot air gun handle (1).

 - The LCD display (8) will begin to blink and show “CAL”.

 - Press UP or DOWN on the control panel (15).

 - Press UP or DOWN using the hot air gun controls (2).

  Press and hold UP or DOWN to rapidly adjust 

values.

•  Press SET on the control panel (15) to save the setting.

g) Sleep Mode 

If the hot air gun temperature is below 100 °C when the hot 

air gun handle is returned to the holder (2), heating will stop 

and the hot air gun will enter sleep mode “SLP”. 

h) Switching Between Hot and Cool Air

The cool air is not actively cooled, it is unheated. The temperature of the cool air will depend on 

the ambient temperature and the temperature of the air exchange system. 

•  Using the hot air gun controls (2), you can toggle between hot and cool air as follows:

 - If hot air is blowing: Press the   button twice to change to cool air, the LCD display (8) 

will show “- - -”.

 - If cool air is blowing: Press the   button once to change to hot air, the LCD display (8) 

will display the actual temperature “REAL”.

SOLDERING STATION

a) Power On

•  Turn the main power switch ON (7).

•  Press the right POWER   button to activate the SOLDERING STATION.

•  The  soldering  iron  will  immediately  begin  heating  until  the  actual  temperature  “REAL” 

matches the set temperature “SET”.

SET

Set Temperature

REAL

Actual Temperature

b) Power Off  

•  Place the soldering iron back into the holder (10)

•  Press  the  right  POWER    button  to  deactivate  the 

SOLDERING STATION.

•  The LCD display (9) will show “OFF”.

•  Turn the main power switch OFF (7).

c) Adjust Temperature

•  If the LCD display does not show “SET”, press the SET button on the control panel. 

•  To adjust the temperature press UP or DOWN on the control panel (15).

  Press and hold UP or DOWN to rapidly adjust 

values.

•  The adjusted values will show on the LCD display (9).

•  Press the SET button on the control panel (15) or wait 

approx. 3 seconds to save the setting.

d) Temperature Shortcut Buttons

Assigning a Shortcut

•  Press the right POWER   button to activate the SOLDERING STATION.

•  Set the desired temperature.

•  Press and hold the right POWER   button together with a shortcut button (12, or 3) for 

more than 5 seconds to assign a shortcut.

•  The temperature will appear on the LCD (9) above the corresponding shortcut button to 

indicate it has been assigned.

SMD REWORK STATION

a) Power On

•  Turn the main power switch ON (7).

•  On the control panel (15), press the left POWER   button to activate the SMD REWORK 

STATION.

 - The hot air gun will start heating up when the handle (1) is removed from the holder (3)

 - The hot air gun will heat up to the temperature that was last set, indicated by “SET” on 

the LCD display (8).

 - The actual temperature is indicated by “REAL” on LCD display (8).

 - The hot air gun will automatically stop heating when the handle (1) is put back into the 

holder (3), and will turn off when the temperature falls below 100 °C. The main unit will 

then enter sleep mode and “SLP” will show on the LCD display (8).

SLP

Sleep/Standby

SET

Set Temperature

REAL

Actual Temperature

b) Power Off

  To prevent product damage, the main unit cannot be turned OFF using the main 

power switch (7) until the hot air gun temperature falls below 100 °C. The main unit 

will automatically assist cooling by sending unheated air through the nozzle (4). Do 

not disconnect the main unit from the power supply during the cool down period. 

•  Press the left POWER   button to deactivate the SMD REWORK STATION. The LCD 

display (8) will show “OFF”.

•  Turn the power switch OFF (7).

Power OFF 

(Temperature >100 °C)

Power OFF

(Temperature <100 °C)

c) Adjust Temperature  

•  If the LCD display (8) does not show “SET”, press the SET button on the control panel (15)

•  The temperature will start to blink.

•  To adjust the temperature:

 - Press UP or DOWN on the control panel (15).

 - Press UP or DOWN using the hot air gun controls (2).

  Press  and  hold  UP  or  DOWN  to  rapidly  adjust 

values.

•  The adjusted temperature will show on the LCD display (8).

•  Press the SET button on the control panel (15) or wait approx. 3 seconds to save the 

setting.

d) 

Airflow Setting 

 

•  If the LCD display (8) does not show “SET”, press the SET button on the control panel (15).

•  Press the   button on the hot air gun handle (1).

•  To adjust the volume of hot air:

 - Press UP or DOWN on the control panel (15).

 - Press UP or DOWN using the hot air gun controls (2).

  Press  and  hold  UP  or  DOWN  to  rapidly  adjust 

values.

•  The amount of air flowing will show on the LCD display (8).

 - The power status bars 

 indicate how much air is flowing.

 - The airflow decreases when the set temperature is reached or is being maintained.

•  Press SET on the control panel (15) or wait approx. 3 seconds to save the setting.

e) Temperature Shortcut Buttons

Assigning a Shortcut

•  Press the left POWER   button to activate the SMD REWORK STATION

•  Press SET to enter settings mode.

•  Adjust the temperature and air volume. 

•  Press and hold the left POWER   button together with 1,2, or 3 on the control panel (15) 

to assign a shortcut 1=“P01”/2=“P02”/3=“P03”.

Summary of Contents for 2108712

Page 1: ...n elektrischen Komponenten oder Bauteilen durch die unter Spannung stehen Trennen Sie solche Komponenten vorher stets von der Stromversorgung Achtung Sollte es einmal vorkommen dass Flüssigkeit in die SMD Lötstation gelangt ist schalten Sie immer zuerst die Netzspannung zur Netzsteckdose ab an der die Lötstation angeschlossen ist Sie müssen den zugehörigen Leitungsschutzschalter abschalten bzw die...

Page 2: ... 7 Hauptschalter ON OFF 8 LC Display SMD REWORK 9 LC Display SOLDERING STATION 10 Lötkolbenhalterung 11 Eingangsbuchse für Lötkolben 12 Schwamm 13 Sicherungshalterung 14 Netzanschluss 15 Bedienfeld Anschluss und Aufstellung Stellen Sie sicher dass sich der Hauptschalter in der OFF Position befindet und das Netzkabel noch nicht an die Stromversorgung angeschlossen ist Die Halterung der Heißluftpist...

Page 3: ...der Halterung 3 befindet und sie schaltet sich aus wenn die Temperatur unter 100 C fällt Das Hauptgerät wechselt dann in den Ruhemodus und auf dem LC Display 8 wird SLP angezeigt SLP Ruhe Standby Modus SET Eingestellte Temperatur REAL Tatsächliche Temperatur b Außerbetriebsetzung Um Schäden am Produkt zu vermeiden lässt sich das Hauptgerät erst dann mit dem Hauptschalter 7 AUSSCHALTEN wenn die Tem...

Page 4: ...n Sie den eingestellten Temperaturwert Schalten Sie die Stromversorgung des Geräts AUS warten Sie 20 Minuten und schalten Sie sie wieder EIN Sollte die Fehlermeldung weiterhin angezeigt werden wenden Sie sich an unseren technischen Kundendienst oder anderes Fachpersonal Pflege und Reinigung a Hauptgerät und Heißluftpistole Beide sind in der Regel wartungsfrei Trennen Sie das Produkt vor der Durchf...

Page 5: ... supply beforehand Caution If liquid does enter the workstation switch off the mains voltage to the socket containing the mains plug switch off at the corresponding circuit breaker or remove the safety fuse and then switch off at the corresponding RCD protective switch You can then unplug the power adapter from the mains socket Discontinue use immediately and take the product to a specialist repai...

Page 6: ... 1 Hot air gun handle 2 Hot air gun controls 3 Hot air gun holder 4 Hot air gun nozzle 5 Main unit carry handle 6 Soldering iron handle 7 Main power switch ON OFF 8 LCD display SMD REWORK 9 LCD display SOLDERING STATION 10 Soldering iron holder 11 Soldering iron input socket 12 Sponge 13 Fuse holder 14 Power socket 15 Control panel Connection and Setup The power switch should be in the OFF positio...

Page 7: ...n 5 seconds to assign a shortcut The temperature will appear on the LCD 9 above the corresponding shortcut button to indicate it has been assigned SMD REWORK STATION a Power On Turn the main power switch ON 7 On the control panel 15 press the left POWER button to activate the SMD REWORK STATION The hot air gun will start heating up when the handle 1 is removed from the holder 3 The hot air gun wil...

Page 8: ...e Disconnect the product from the mains and allow all parts to cool down completely before each cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Clean the product with a dry fibre free cloth b Soldering Iron Always keep the tip tinned before switching off or storing for any period of time Never...

Reviews:

Related manuals for 2108712