•  Check the product for damage before each use! If you notice any damage, do not 

use the product any longer! Disconnect it from the mains voltage and pull the plug 

out of the power socket. Take the product to a specialised workshop.

•  The device must only be repaired by a specialist or in a specialist workshop.
•  Our technical support is available, if you have queries about the use of the device 

which have not been answered in these operating instructions.

Installing the placement station   

In order to avoid burns, it is recommended to safely place the hot 

air nozzle on the placement station.
There are two oblique threaded holes at the left and right sides of 

the housing, which can be used to fasten the placement station.

Before operation

  Please make sure that the hot air nozzle is cold!

 

If the hot air nozzle is still warm/hot, let it cool down first.

1.  Select a nozzle adapter that corresponds to the size of the work piece!
2.  Loosen the screw at the nozzle adapter and place it on the hot air nozzle.
3.  Fasten the nozzle adapter! Do not tighten the screws too much! Do not use force and pull 

the nozzle adapter with pincers!

Operation (switching on and off)

  Also observe the section „Safety instructions“!

1.  First, put the device on a level, firm and sturdy surface.
2.  Plug the main plug into the wall socket - the automatic blower feature is thus activated!
3.  Turn on the device! (POWER: ON = On). The heater immediately starts heating up when 

powered on. Check on the display whether the desired temperature unit °C or °F is shown. 

Follow the instructions provided in the Chapter “Settings” to change this. 

4.  You can set the desired hot air temperature by the temperature control “SET TEMP”. The 

red light indicator next to the rotary knob indicates the active temperature setting. If lit, the 

temperature can be adjusted while you turn the knob, the desired target temperature is 

displayed. About 3 seconds after the temperature has been set, the display switches to the 

actual temperature. As soon as the preset value is shown on the display, you can start 

soldering.

5.  Now set the air flow rate with the controller (AIR) and wait a bit until the temperature is 

stable! On the display the air flow is shown by the indicators A25 to A99. A25 is the lowest 

air flow velocity, while A99 is the highest. The display switches back to the temperature 

display after approx. 2 seconds.

6.  After your work is finished, turn off the device using the main switch (POWER OFF). Now 

the automatic blower feature blows cool air through the tube to cool down the temperature 

of the heating element and the handle to below 100 °C. Therefore, do not unplug the main 

plug from the wall socket as long as the cooling process is not done! Cooling takes approx. 

1 minute. The process of cooling is indicated on the display. When the temperature has 

fallen to 100 °C, the device turns off automatically a short while later.

Settings 

1.  Selecting the temperature unit

To change the temperature unit from °C to °F or vice versa, turn off the device by the main 

switch “POWER OFF”. Wait until the device has cooled off, the blower and indicators as 

well.
Press and hold the red button while switching on the device by the main switch “POWER 

ON”. The temperature unit in the display is changed by means of this procedure. The unit 

is stored also after the device is turned off.

2.  Automatic switch-off time

After the adjustable switch-off time has passed, the device automatically puts the heater 

and the pump of the soldering tool in the standby mode. The device remains switched on, 

and is easily activated again by pressing the red button. On delivery, this function is 

deactivated and set to “OFF”.
In order to activate this function, press and hold the red button. The display shows “- - -”.
Adjust the desired switch-off time with the control button “AIR”. The adjustment range can 

be set between 20 to 600 seconds. Selecting the indication “OFF” deactivates this function. 

Release the red button. The value is stored and maintained after turning the device off.

 Operating instructions

Hot Air Soldering/Unsoldering AT 850D

Item no. 588074

Intended use

This hot air soldering/unsoldering system is suitable for soldering and unsoldering SMD- and 

micro components, DIP and Flat Pack ICs as well as for shrinking and heating plastics and 

metals, for removing labels etc. Temperature and airflow are adjustable - shot warming-up time. 

Working with hot air enables an ESD-safe working without contact with the work piece. Four 

nozzles are included in the delivery.
This product is only approved for connection to 230 Volts / 50 Hz (10/16 A) alternating volt-

age and designed for indoor use. The product must not be operated outdoors and in humid 

environments!
The product’s design corresponds to Protection Class 1. Use only a properly grounded wall 

socket of the public power network as a voltage source. The main socket must be located near 

the equipment and easily accessible, or an emergency shut-down must be in place.
Operating the product in any way other than the one described above is not permitted and may 

lead to damage of the product, which can increase risks such as short circuit, fire and electric 

shock. Always observe the safety instructions included in these operating instructions. Read 

the operating instructions carefully and keep them for later reference.

Up-to-date operating instructions        

Download the latest operating instructions via the link www.conrad.com/down-

loads or scan the QR code. Follow the instructions on the website.

Safety instructions     

The warranty will be void in the event of damage caused by failure to observe 

these safety instructions.
We do not accept liability for damage to property and injury to persons caused 

by mishandling or non-compliance with the safety instructions!
An exclamation mark indicates that important notes in these operating in-

structions should always be observed.
•  The device must not be modified or converted, as not only the CE approval will 

become void but so will the warranty.

•  Products operated using the mains voltage must be kept out of the reach of chil-

dren. For this reason, be particularly cautious when using the products in the pres-

ence of children. They may try to stick objects into the device through openings in 

the housing. There is a perilous electric shock danger and risk of burning.

•  Never pour any liquids onto electric devices and do not place any liquid-filled ob-

jects onto or close to them. You run the risk of causing a fire or a fatal electric 

shock.

•  Use the product in dry indoor areas only. It must not get damp or wet. Otherwise, 

there is a life-threatening danger due to electric shock!

•  Never plug in the product directly after transferring it from a cold to a warm room. 

The condensation that develops in such cases could damage the device or cause 

an electric shock. Allow the appliance to reach room temperature. Wait until the 

condensation has evaporated. This might take several hours. Only after this 

should it be plugged in to the mains supply and put into use.

•  Do not carelessly leave the packaging material lying around since this may be-

come a dangerous toy for children.

•  In commercial institutions, the accident prevention regulations of the employer’s 

liability insurance association for electrical systems and operating facilities are to 

be observed!

•  If you should have reasons to assume that safe operation is no longer ensured, 

turn off the device and secure it against accidental use. Safe operation is no longer 

ensured, when:

 - The device shows visible signs of damage or no longer functions.
 - The power cable or plug is worn or otherwise damaged.
 - The device has been stored under unfavourable conditions for a longer period 

of time.

 -  The device has been exposed to strong stress during transport.

•  The product must not be exposed to high mechanical pressure.
•  The product must not be exposed to extreme temperatures, direct sunlight, in-

tense vibration or humidity.

Summary of Contents for AT 850D

Page 1: ...rd gespeichert und bleibt auch nach dem Ausschalten erhalten Bedienungsanleitung Heißluft Löt Enlötsystem AT 850D Best Nr 588074 Bestimmungsgemäße Verwendung Dieses Heißluft Löt Enlötsystem eignet sich zum Löten und Entlöten von SMD und Micro Bauelementen DIP und Flat Pack IC s sowie zum Schrumpfen Erwärmen von Kunststoffen und Metallteilen zum Ablösen von Etiketten usw Die Temperatur und der Luft...

Page 2: ...üse so dass sich der Düsenaufsatz z B direkt über dem IC befindet Ein direkter Kontakt von IC und Aufsatz muss unbedingt vermieden werden Durch die ausströmende Heißluft beginnt das Lötzinn zu schmelzen 2 Sobald das Lötzinn geschmolzen ist entfernen Sie bitte das IC mit einer Zange oder Pin zette 3 Nachdem Sie das IC entfernt haben können Sie das restliche Lötzinn mithilfe einer Ent lötsaugpumpe e...

Page 3: ...Selecting the indication OFF deactivates this function Release the red button The value is stored and maintained after turning the device off Operating instructions Hot Air Soldering Unsoldering AT 850D Item no 588074 Intended use This hot air soldering unsoldering system is suitable for soldering and unsoldering SMD and micro components DIP and Flat Pack ICs as well as for shrinking and heating p...

Page 4: ...le to disconnect the device from the mains Unsoldering 1 To melt the tin solder hold the hot air nozzle so that the nozzle adapter is positioned di rectly over the IC Direct contact between IC and adapter must absolutely be avoided The tin solder starts melting due to the emitting hot air 2 Please remove the IC with pincers or tweezers as soon as the tin solder is melted 3 After you have removed t...

Page 5: ...ort Le produit ne doit pas être soumis à de fortes contraintes mécaniques Le produit ne doit pas être exposé à des températures extrêmes aux rayons di rects du soleil à de fortes vibrations ou à l humidité S assurer avant chaque utilisation que le produit ne présente aucun endom magement Au cas où vous constateriez un endommagement n utilisez plus le produit Débrancher le bloc d alimentation de la...

Page 6: ... buse d air de sorte que l extension de la buse se trouve par ex directement au dessus de l IC circuit intégré Tout contact direct entre IC et extension doit impérativement être évité L air chaud soufflé commence à fondre l étain 2 Dès que l étain est fondu enlever l IC à l aide d une pince ou d une pincette 3 Après le retrait de l IC l étain résiduel peut être éliminé avec une pompe de débrasage ...

Page 7: ...llen Het product niet blootstellen aan extreme temperaturen direct zonlicht sterke trillingen of vochtigheid Controleer het product vóór elk gebruik op beschadigingen Indien u beschadigin gen constateert dient u het product niet meer te gebruiken Koppel het los van de netspanning en haal de stekker uit de contactdoos Breng het product vervolgens naar een reparatiedienst Laat het apparaat uitsluite...

Page 8: ...t smelten van het soldeertin houdt u de hete luchtnozzle zo dat het opzetstuk zich bijv direct boven de IC bevindt Een direct contact van IC en opzetstuk moet absoluut worden vermeden Door de uitstromende hete lucht begint het soldeertin te smelten 2 Zodra het soldeertin is gesmolten verwijdert u de IC met een tang of pincet 3 Nadat u de IC hebt verwijderd kunt u de overgebleven soldeertin met beh...