The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
4. Technical data
Power supply:
230 ~ 50 Hz
Motor rating in kW/HP:
1.1/1,5
Operating mode
S3 25% 10 min
Compressor speed in rpm:
3550
Operating pressure in bar:
8
Pressure vessel volume in litre:
6
Theoretical intake rate in l/min.:
180
Sound power level L
WA
in dB:
94.5
Sound pressure level L
pA
in dB:
74.5
Protection type:
IP 20
Machine weight in kg:
9,1
Operating mode S3 - 25% - 10min: S3 = Intermittent
mode without influencing the starting process. This
means that during a period of 10 min the max.
operating time is 25% (2.5 min).
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines
(extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
6.1. Fitting the supporting feet (3)
Fit the supplied supporting feet (4) as shown in Fig.
3.
6.2. Assembly of the quick-lock coupling (4)
Screw the quick-lock coupling (5) to the appliance as
shown in Fig 4-5.
6.3 Voltage
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any
230V ~ 50Hz shock-proof socket which is protected
by a 16 A fuse. Before you use the machine, make
sure that the mains voltage complies with the
specifications on the rating plate. Long supply
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
jeopardized as a result of stiffness.
6.4 On/Off switch (8)
To switch on the equipment set the On/Off switch (8)
to position 1.
Move the On/Off switch (8) to position 0 to switch off
the equipment.
6.5 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
7. Cleaning and maintenance
Important!
Pull the power plug before doing any cleaning
and maintenance work on the appliance.
Important!
Wait until the compressor has completely cooled
down. Risk of burns!
Important!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
UK
22
Original operating instructions
Anleitung_TMAC_160_OF_SPK7:_ 08.04.2011 8:58 Uhr Seite 22
Summary of Contents for 40.101.52
Page 1: ...Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 57 Uhr Seite 1...
Page 3: ...3 1 2 2 4 10 3 4 1 9 11 7 6 5 8 3 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 3...
Page 4: ...4 4 5 5 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 4...
Page 25: ...25 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 25...
Page 30: ...30 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 30...
Page 31: ...31 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 31...
Page 36: ...EH 04 2011 01 Anleitung_TMAC_160_OF_SPK7 _ 08 04 2011 8 58 Uhr Seite 36...