background image

Zeus200 

                                                           User Manual 

V 1.0.8 

– 12/10/2020 

          Page 14 of 16 

Error 

Possible cause 

Possible solution 

Display shows  
“Fuel Pump error”

 

- Fault or lack of 
connection to the fuel 
pump 

 

- Contact an authorized center for 
verification

 

Displa

y shows “External pump 

er

ror” 

- Obstruction of the 
water inlet 
- Pump not working 
- Exchanger blocked 

- Check and clean the water inlet 
and outlet from any external bodies 
- Clean exchanger 
- Contact an authorized center for 
verification

 

 

Display shows 
“Water pump error”

 

- Fault or lack of 
connection with water 
pump

 

- Contact an authorized center for 
verification

 

Display shows  
“Spark plug fault”

 

- Fault or lack of 
connection with the 
spark plug

 

- Contact an authorized center for 
verification

 

Display shows  
“Water overtemperature”

 

- Coolant temperature 
too high

 

- Wait for the coolant temperature 
to drop

 

Display shows  
“Water outlet probe error”

 

- Fault or lack of 
connection with outlet 
water probe

 

 

- Contact an authorized center for 
verification

 

Display shows  
“Water inlet probe error”

 

- Fault or lack of 
connection with inlet 
water probe

 

- Contact an authorized center for 
verification

 

Display shows  
“Fume probe error”

 

- Fault or lack of 
connection with exhaust 
gas probe

 

- Contact an authorized center for 
verification

 

Display shows  
“Low coolant liquid level”

 

- Insufficient cooling 
liquid

 

- Top up the coolant through the 
cap on the generator exchanger. 
ATTENTION: for topping up, use 
only coolant for violet type engines 
with gradation 

≤-30°C, ≥120°C. 

The use of different liquids 
compromises both the use and the 
warranty

 

 

Display shows  
“Wait for cooling”

 

- Generator temperature 
too high to be able to 
perform a new ignition

 

- Wait for the system to cool down

 

Battery charges too fast 

- Exhaust battery, not 
able to store energy 
anymore 

- Replace battery 

Battery does never charge 

- One or more elements 
damaged or sulfated; 
battery does not reach 
charge voltage level 

 

 

- Replace battery 

Summary of Contents for ZEUS200 BD

Page 1: ...r USER MANUAL ZEUS200 BD Power Supply Diesel IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on support mobiltech it More information can be found in c...

Page 2: ...ble of charging the batteries of your boat regardless of the availability of external electricity or weather conditions Installation and commissioning must be performed by specialized personnel only u...

Page 3: ...rking The operation is very harmful because the cooling of the device will be lost causing possible breakages due to overheating Any incorrect operation is recorded in the device memory General notes...

Page 4: ...ash the generator using a pressure washer The generator is not designed to work submerged in water or other liquids in the event of flooding the warranty becomes void and it is necessary to go to an a...

Page 5: ...the menu structure is shown HOME SETTINGS TIMER MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Timer 1 Timer 2 Clock Automatic Manual Battery automatic selection Engine battery forcing Italian English...

Page 6: ...Manual mode generator not active The solar panel icon will be on only if the solar panel is charging The blue arrows with a continuous line indicate which of the energy sources is in operation and wh...

Page 7: ...ntly both graphically and numerically 2 1 2 Thermoelectric generator management Pressing the generator icon the screen display the Menu related to the energy supplied by the thermoelectric generator T...

Page 8: ...e to charge 12V and 24V secondary batteries The battery data is displayed on the left Type Actual voltage The percentage of engine battery charge is displayed on the right side of the screen Battery d...

Page 9: ...wo available Timers as well as the internal clock To set a timer press the related time and make the desired adjustments in the central part of the screen When the two timers are activated the related...

Page 10: ...the primary battery services with respect to the secondary one engine Nevertheless the latter is constantly monitored and if its voltage falls below a minimum value it will be immediately charged Bat...

Page 11: ...ers Software update The two icons at the bottom right display the status of communications between the different components of the system C communication between the display unit and the power unit G...

Page 12: ...ve on three different colors Gray working element actually not active Blue working element actually active Red failed element error issued In case of error it can be reset by pressing the relative ico...

Page 13: ...service battery in a more ventilated place Display shows Engine batt low Low voltage of engine battery Turn on the generator and force the charge on the engine battery Switch on vehicle s engine if p...

Page 14: ...let probe error Fault or lack of connection with outlet water probe Contact an authorized center for verification Display shows Water inlet probe error Fault or lack of connection with inlet water pro...

Page 15: ...sidering the fact that the generator produces energy based on the thermal delta the production of energy varies according to the sea temperature In addition the system can be affected by other factors...

Page 16: ...ch it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of oper...

Reviews: