Zeus200
User Manual
V 1.0.8
– 12/10/2020
Page 4 of 16
recharged when the primary is charged or the secondary is under the minimum working
level
•
The primary battery is recharged using the parameters related to the temperature of the
containment compartment. It is possible to force a priority charging of the secondary
battery
•
If the display is not touched for 3 minutes, it switches off automatically while keeping the
set functions unaltered. To turn it on again simply touch the screen
•
If manual mode, after 30 minutes of inactivity the system automatically goes into stand-by
mode to reduce electrical consumption. When switched on again, it may take a few
seconds to restore communication with all components
•
The generator switches off automatically 3 minutes after the ignition of the vehicle engine.
Within the first 3 minutes there is the possibility to force the generator working status
confirming the popup message on the display
•
Use only batteries of type PB / AGM / GEL and LiFeP04, selecting the correct charging
algorithm from the control unit.
•
Recommended capacity: from 100 to 600Ah. Do not use old batteries in any
circumstances, as they could cause the Zeus200 generator not to work correctly
•
In any moment is possible to check the status and characteristics of the batteries
•
It is always possible to check the operating status of the system and all its components
•
Do not wash the generator using a pressure washer
•
The generator is not designed to work submerged in water or other liquids; in the event of
flooding, the warranty becomes void and it is necessary to go to an authorized installer.
•
The generator manufacturer is not responsible for battery status or incorrect selection of
the type of batteries to be recharged
1.3 Fuel quality
Diesel Generator
The Zeus200 generator works without problems with the diesel fuel normally
available on t
he market used for the vehicle’s engine. Addition max. of biodiesel available on the
market according to DIN EN 590. In the winter months diesel fuel is adapted at low
temperatures from 0°C to -20°C. In this way problems can arise only in the case of extremely
low external temperatures - as well as in the boat engine - see the instructions of the
manufacturer. In special cases and at external temperatures above 0°C the Zeus200 generator
can also work with heating oil sec. DIN 51603 (from an additional tank).
If the Zeus200 generator is powered from a separate tank, follow these steps:
•
external temperatures higher than 0°C: use diesel oil sec. DIN EN 590 or heating oil sec.
DIN 51603;
•
external temperatures from 0°C to -20°C: use winter diesel sec. DIN EN 590;
•
outside temperatures from -20°C to -40°C, use arctic gas oil or polar gas oil.
The addition of used oil is allowed. After using winter diesel or diesel fuel for low temperatures,
fill the fuel lines and the standard diesel fuel pump by running the generator for 15 minutes. The
Zeus200 generators are not approved to work with bio-diesel according to DIN EN 14214.