background image

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment to a different circuit than the one the receiver is

connected to.

• Consult your supplier or an experienced radio/TV technician for help.

Caution

: Any changes or modifications not expressly approved by the party

responsible for compliance could void the user's authority to operate the
equipment.

18

Summary of Contents for TS04

Page 1: ...DIGITAL MULTIMETER USER S MANUAL TS04 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...ng Auto Power Off 9 Measuring AC or DC Voltage 9 Measuring AC or DC Current 9 10 Measuring Resistance 11 Measuring Temperature 11 Checking for Continuity 12 Checking the Integrity of a Diode 12 Checki...

Page 3: ...outlets in a rendering of a room as a way to compare their efficiency KEY FEATURES 10 functions 26 ranges Measures AC DC voltage AC DC current resistance and surface temperature Also checks continuit...

Page 4: ...tary dial in the or position 2 Selects resistance measurement continuity checking or diode checking with the rotary dial in the position 3 Toggles between C and F units with the rotary switch in the T...

Page 5: ...nits 15 Measured value SAFETY INSTRUCTIONS Warning To avoid possible electric shock or personal injury and to avoid damaging the meter or the equipment under test Before using the meter inspect the ca...

Page 6: ...hen making connections connect the black test lead before connecting the red test lead when disconnecting disconnect the red test lead before disconnecting the black test lead Disconnect circuit power...

Page 7: ...male terminal plugging into the larger female terminal 4 Secure the battery compartment by replacing the cover stand and reinstalling and tightening the Phillips head screw 7 Electrical Symbols Used O...

Page 8: ...tes operation in Auto Ranging mode To switch to Manual Ranging mode for any parameter briefly press the RAN button This will make the AUTO term disappear and cause the meter to enter the widest full s...

Page 9: ...button once this will cause the icon to replace the icon on the left side of the LCD If you are unsure whether the voltage to be tested is AC or DC configure the DMM to measure AC voltage for safety r...

Page 10: ...oltage for safety reasons 4 Plug the black test lead into the black COM jack at the bottom left of the front panel 5 Plug the red test lead into the A or jack Choose the A jack if you have set the rot...

Page 11: ...ng in Manual Ranging mode and the readout is OL the resistance value is beyond the currently selected range If that is the case use the FUNC button to select the next widest position MEASURING TEMPERA...

Page 12: ...ipment turn off the power source and discharge all high voltage capacitors 1 Turn the function switch to the position and press the FUNC button until the icon appears in the upper right corner of the...

Page 13: ...ing the top within 1 4 inch of it after moving the rotary function switch to the NCV position If the beeper sounds repeatedly and the red LED at the top of the meter Fig 1 Callout 10 flashes rapidly t...

Page 14: ...0mA 400mA 10A current Measurement accuracy 2 of reading 3 digits in 10A range 1 2 of reading 6 digits or better in other ranges Maximum resolution 0 1 A Resistance Measurement ranges 0 to 400 4k 40k 4...

Page 15: ...otection 400mV 600V fuse for jack 10A 600V fuse for A jack Sampling time 3X sec Display No of digits 3 3 4 Maximum count 4000 Low battery indication threshold 6 7VDC Operating temperature 32 to 104 F...

Page 16: ...fferent white cylindrical fuses The jack is protected by an F400mA 600V fuse The A jack is protected by an F10A 600V fuse Each fuse is located directly behind the jack it protects 7 Using another mult...

Page 17: ...d to implied warranties of merchantability and fitness for a particular purpose are limited to the above General shall not be liable for loss of use of the product or other incidental or consequential...

Page 18: ...ordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does...

Page 19: ...____________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________...

Page 20: ...RAL TOOLS INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS MAN TS04 01 14 16 General Tools Instruments GeneralToolsNYC 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll F...

Reviews: