EN
English –
5
Toona series 7
Type
electromechanical gear motor for gates or doors with leaf opening
Power input
24 Vdc
Maximum absorption
5 A
Nominal absorption
2.5 A
Maximum absorbed power
120 W
Nominal absorbed power
60 W
Protection grade
IP 44
Travel
584 mm
Speed loadless
0.013 m/sec
Speed loaded
0.011 m/sec
Maximum force
2700 N
Nominal force
1400 N
Operating temperature
-20 °C to +50 °C
Cycles/h at nominal force
41
Durability
estimated between 80,000 and 250,000 cycles of manoeuvres according to the conditions set out in Table 2
Insulation class
F
Dimensions (mm)
1200 x 128 x 150 h
Weight
15 Kg
TO7024
Durability of the product
Durability is the average economic life of the product. The value of durability is strongly influenced by the demand index of the manoeuvres performed by the
automatism: that is the sum of all the factors which contribute to the wear of the product (see Table 2).
To establish the probable durability of your automatism proceed as follows:
01.
Calculate the demand index summing the values in percentage of the entries present in
Table 2
to each other;
02.
In
Graph A
, from the value just found, trace a vertical line until you intersect the curve; from this point trace a horizontal line to cross the line of “cycles of
manoeuvres”. The value established is the estimated durability of your product.
The estimate of durability is performed on the basis of the design calculations and the results of tests carried out on prototypes. In fact, being an estimate, it does
not give any guarantee on the actual duration of the product.
Example of calculation of durability of a Toona series 5 gear motor (refer to Table 2 and Graph A):
- leaf weight = 350 Kg (demand index= 10%)
- leaf length = 3.5 m (demand index = 10%)
- no other stress elements present
Total demand index = 20%
Durability estimate = 160,000 cycles of manoeuvre
0
0
50.000
80.000
100.000
150.000
200.000
250.000
10
20
3
0
40
50
60
70
80
90 100
Toona 4
Toona 5
Toona 7
Demand index
> 200 Kg
10 %
0 %
0 %
Leaf weight:
> 300 Kg
20 %
10 %
0 %
> 400 Kg
30 %
20 %
10 %
> 500 Kg
-
30 %
20 %
2 - 3 m
20 %
0 %
0 %
Leaf
3 - 4 m
-
10 %
0 %
length:
4 - 5 m
-
20 %
10 %
5 - 6 m
-
-
20 %
6 - 7 m
-
-
30 %
Ambient temperature greater
than 40°C or lower than 0°C
20 %
20 %
20 %
or humidity greater than 80%
Blind leaf:
15 %
15 %
15 %
Installation in windy area:
15 %
15 %
15 %
TABLE 2
GRAPH A
Demand index (%)
cycles of manoeuvr
e
s
Summary of Contents for TO4005
Page 2: ......
Page 9: ...EN IT FR ES DE PL NL IX EN Images ...
Page 16: ...XVI 7 6 D E A B C ...
Page 17: ...XVII 2 1 9 8 Toona 4 5 F 44 mm Toona 7 F 50 mm F ...
Page 18: ...XVIII 1 2 3 10 2 3 1 Toona 4 5 Toona 7 ...
Page 19: ...XIX 12 11 100 mm max Toona 4 5 Toona 7 ...
Page 20: ...XX 2 1 14 1 2 13 ...
Page 21: ...XXI 1 3 2 16 ENC M M AP COM CH 15 Toona 4 5 24 V Toona 7 24 V 24 V 230 V Toona 4 5 230 V ...
Page 22: ......
Page 23: ......