11
It is recommended to position the ECO-ClimaTEC horizontal with its
liquid connectors to the side of the vehicle because of the level
fluctuations of the liquid caused by accelerations.
It is important to clear some space around the ECO-ClimaTEC for
the heat expel of the internal electric components in the device.
There is no need for an additional forced air flow as long as
sufficent heat expel is maintained for the unit.
RADIATOR/FAN COMBINATION (EXTERIOR LOOP) [EEM]
Step 2.
Place and connect the exterior radiator/fan
To create a high performance cooling
system it is very important to expel
sufficient heat in the exterior loop.
Therefore this loop must be connected
to a radiator/fan combination with
adequate performance.
Depending on the system
It is recommended to use a
combination that is able to expel
approximately 150 to 200 W/°C.
It’s preferred to enter the
tubing
Preferred orientation of the ECO-ClimaTEC in the vehicle
Radiator/fan
combination
(exterior loop)