6. COORDINATE MEASUREMENT
6-2
6.2 Setting
Coordinate of Instrument Point
Set the coordinates of AP-L1A/L1AN according to the coordinate original point, and AP-L1A/L1AN
automatically measures, converts, and displays the unknown point (prism point) coordinates. It is
possible to retain the coordinate of the instrument point after turning power switch OFF. Refer to
Chapter 15 "Special mode (Menu key operation)".
However, when the instrument is powered off, the value of the instrument height will be erased.
Instrument height will need to be reentered.
6.2.1.
How to Input Instrument Coordinate Value Directly
Confirm the mode is set in angle or distance measuring mode.
Example: N coordinate 12.345m, E coordinate 54.321m, Z coordinate 2.345m,
Instrument
height
1.3m
Operating procedure
Operating key
Display
Press [F4](
)key 4 times to be function
as in page 5.
[F4]
4 times
V
:
90
10
'
20
"
H R
:
120
30
'
40
"
0SE T
H SE T
R/L
1
BS
CSE T
RST
5
Press [F2](CSET)key.
[F2]
OCC.
P OINT
N :
0.0000
m
E
:
0.0000
m
E XIT
CLR
Input N coordinate.
Example: N coordinate: 12.345m
1
2
.
3 4 5
[ENT]
OCC.
P OINT
N :
12.3450
m
E
:
0.0000
m
E XIT
CLR
Input E coordinate.
Example:E coordinate: 54.321m
5
4
.
3 2 1
OCC. POINT
N :
12.3450 m
E :
54.3210 m
EXIT
CLR
Prism(N,E,Z)
N
Origin(0,0,0)
E
N
E
Instrument point C
z
Summary of Contents for AP-L1A
Page 1: ...INSTRUCTION MANUAL AUTOMATIC TRACKING TOTAL STATION AP L1A AP L1AN...
Page 14: ...1 NOMENCLATURE AND FUNCTIONS 1 3 2 The details of label will be differed by the market...
Page 82: ...11 SETTING ATMOSPHERIC CORRECTION 11 4 Temprerature C Temprerature F...
Page 83: ...11 SETTING ATMOSPHERIC CORRECTION 11 5 Temprerature F...