6. COORDINATE MEASUREMENT
6-6
13
Press [F3](YES) key.
4)
The instrument rotates and the
telescope turns to inverted position
automatically and the measurement of
the known point B starts.
3)
When the measurement of point B is
completed, the instrument rotates and
starts the measurement of known
point A in inverted position .
3)
When the measurement of known point
A is completed, the instrument rotates
and the telescope turns to the normal
position automatically .
Vertical angle error (dVA,dVB) and
horizontal angle discrepancy (dH) will
be displayed.
5)
[F3]
V
:
269
39
'
15
"
H R
:
250
30
'
40
"
P OINT
B ( 2 )
CH E CKING
ME ASURING
SE T ! !
V
:
269
49
'
50
"
H R
:
190
20
'
35
"
P OINT
A ( 2 )
CHE CKING
MEASURING
SET ! !
RETURN
A
dVA: :
0
00
'
10
"
dVA:
-0
00
'
15
"
dH :
0
00
'
05
"
SE T
OK
[ YES ][ NO ]
14
Confirm the vertical angle error and
horizontal angle discrepancy and press
[F3](YES) key.
6)
Discrepancy (dHD) and discrepancy
(dZ) will be displayed.
7)
[F3]
dH D
&
dZ
dH D:
-0.0012
m
dZ:
0.0023
m
SE T
OK
[ YES ][ NO ]
15
Confirm the discrepancy , and press
[F3](YES) key.
8)
The coordinate of the instrument point
will be displayed.
[F3]
N
:
1.2345
E
:
2.3456
Z
:
-3.4567
SE T
OK
[ YES ][ NO ]
16
Confirm the coordinate of instrument
point , and press [F3](YES) key.
Setting coordinate value of the
instrument is completed, the display
returns to the previous measurement
mode .
9)
[F3]
V
:
90
10 '20"
HR :
10
20' 30"
BS CSET RST 5
1) Selecting 2D, will be omitted following input of instrument height, Z-Coordinate value, and prism
height.
2) In order to set value of the instrument height, use the soft key (CSET).
Summary of Contents for AP-L1A
Page 1: ...INSTRUCTION MANUAL AUTOMATIC TRACKING TOTAL STATION AP L1A AP L1AN...
Page 14: ...1 NOMENCLATURE AND FUNCTIONS 1 3 2 The details of label will be differed by the market...
Page 82: ...11 SETTING ATMOSPHERIC CORRECTION 11 4 Temprerature C Temprerature F...
Page 83: ...11 SETTING ATMOSPHERIC CORRECTION 11 5 Temprerature F...