41
Leveling measurement 2: B1
→
B2
→
F1
→
F2
Operating Procedures
Operation
Display
1. After inputting the ground
height of backsight point, the
screen will display “Bk1
(backsight).If the previous step is
“Start Leveling”, screen will
display BM (Bench Mark).
2. Sight at the staff in the
backsight point (Bk1) and Press
[MEAS] key.
3. Focus and sight at the staff in
the backsight point (Bk2) and
press [MEAS].
4. Sight at the staff in the
foresight point [Fr1].
Meanwhile press [ESC] can
change the foresight point name.
Press [MEAS] to measure.
5. Sight at the staff in the
foresight point (Fr2) and press
[MEAS].
6. Move the station and sight at
Sight at Bk 1
[MEAS]
Sight at Bk 2
[MEAS]
Sight at Fr1
[MEAS]
Sight at Fr2
[MEAS]
Level BBFF
Fr1
PN:P01
Press [MEAS] to meas
Level BBFF
Bk1
BM#:B01
Press [MEAS] to meas
Level BBFF
Bk1
BM#:B01
>>>>>>>>>>>
Level BBFF
Bk2
BM#:B01
Press [MEAS] to meas
Level BBFF
Fr2
PN:P01
Press [MEAS] to meas