3-4
3 ANGLE MEASUREMENT
3.5 Repetition Angle Measurement
•
Repetition angle measurement can be done by horizontal angle right measurement mode.
Make sure the mode is Horizontal Angle Right measurement.
Operating procedure
Operation
Display
1
Press the
{F4}
(
↓
) key to get the function on page
2.
{F4}
2
Press the
{F2}
(REP)key.
{F2}
3
Press the
{F3}
(YES) key.
{F3}
4
Collimate the target A and press the
{F1}
(0SET)
key.
Collimate A
{F1}
5
Press the
{F3}
(YES) key.
{F3}
6
Collimate the target B using the horizontal clamp
and tangent screw.
Press the
{F4}
(HOLD) key.
Collimate B
{F4}
7
Recollimate target A using the horizontal clamp
and tangent screw, and press the
{F3}
(REL)key.
Collimate A
{F3}
8
Recollimate target B using the horizontal clamp
and tangent screw, and press the
{F4}
(HOLD)
key.
Collimate B
{F4}
9
Repeat
7
to
8
to measure the desired number of
repetitions.
[Example] 4 measurement
V :
90°10'20"
HR:
170°30'20"
0SET HOLD HSET
P1
↓
TILT REP V%
P2
↓
REPETITION ANGLE
>OK?
--- --- [YES][NO]
REP-ANGLE COUNT[ 0]
Ht: 0°00'00"
Hm:
0SET V/H REL HOLD
REPETITION ANGLE
INITIALIZE
>OK?
--- --- [YES][NO]
REP-ANGLE COUNT[ 0]
Ht: 0°00'00"
Hm:
0SET V/H REL HOLD
REP-ANGLE COUNT[ 1]
Ht: 45°10'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 1]
Ht: 45°10'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 2]
Ht: 90°20'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 4]
Ht: 180°40'00"
Hm: 45°10'00"
0SET V/H REL HOLD