4-4
4 DISTANCE MEASUREMENT
4.5 Fine Mode/Tracking Mode/Coarse Mode
This setting is not memorized after power is off.
Refer to Chapter 17 “SELECTING MODE” to set at the initial setting (memorized after power is off).
Fine Mode
: This is a normal distance measuring mode.
The unit to be displayed can be changed.
Measurement time will vary depending on the unit to be displayed.
Tracking Mode : This mode measures in shorter time than in fine mode.
It is very useful when tailing the moving object or carrying out stake-out work.
Coarse Mode
: This mode measures in shorter time than in fine mode.
The unit to be displayed can be changed.
To change the unit to be displayed in fine mode, see Chapter 17 “SELECTING MODE” and to
change the unit in course mode, see section 6.4.1 “Setting Minimum Reading”.
For the details of the unit and measurement time in each mode, see Chapter 26
Operating procedure
Operation
Display
1
Press the
{F2}
(MODE) key from the distance
measuring mode.*1)
The initial character (F/T/C) of set mode is
displayed. (F:Fine, T:Tracking, C:Coarse)
{F2}
2
Press the
{F1}
(FINE) key,
{F2}
(TRACK) key, or
{F3}
(COARSE) key.
{F1}
~
{F3}
*1) To cancel the setting, press the
{ESC}
key.
HR: 120°30'40"
HD* 123.456m
VD: 5.678m
MEAS MODE NP/P P1
↓
HR: 120°30'40"
HD* 123.456m
VD: 5.678m
FINE TRACK COARSE F
HR: 120°30'40"
HD* 123.456m
VD: 5.678m
MEAS MODE NP/P P1
↓