Microprocessor
:
XScale PXA 255
Processor speed
:
400MHz
Operating system
:
Microsoft Windows CE.NET 4.2
Memory
:
64MB RAM
64MB/128MB flash disc (internal)
Display
:
240x320 QVGA (color)
3.5 inch TFT Transflective type
Illumination
:
LED back light
Keyboard
:
10 keys (“power key” included)
Pen touch screen
:
Resistive touch screen/passive Pen digitization
Interface
:
RS-232C serial (D-sub 9)
USB(Rev1.1)(Mini-B)
CompactFlash : Type I /ll
SD Memory card
External power
:
12V 1A(MAX)
Audio
:
Sealed Speaker (mono) Sealed Microphone
Durability
:
IP66 (Based on the standard IEC 60529)
*1)
*1) With the connector and card slot caps
Operation
temperature
:
-20°C to +50°C (-4°F to +122°F)
Storage
temperature
:
-30°C to +60°C (-22°F to +140°F)
Protection against
shock
:
Dropping this instrument from a height of 1 meter does not affect its func-
tions.
Conditions:
Each of the instrument’s 6 sides was dropped onto a concrete
surface, and the instrument’s operation was then confirmed.
Only the exterior of the instrument was damaged.
EMC
:
CE, FCC
Battery BT-62Q
:
Li-ion rechargeable Battery 7.4V 2200mAh
(This battery does not contain mercury.)
Operating time
:
20 hours (Typical use )
45 hours (With no display light, no touch)
Charging time
:
Approx. 5.0 hours with AD-9B/7C
Dimensions
:
182x103x59(mm)
Weight
:
0.6kg(with battery)
Battery Installation
1
Using a coin, loosen the cover screw on the battery cover.
2
Remove the battery cover.
3
Install the battery pack.
(Cconfirm the direction of battery installation.)
4
Using a coin, install the battery cover. Tighten the cover
screw firmly.
STORAGE PRECAUTIONS
SPECIFICATIONS
Always clean the instrument after use.
Use a clean cloth moistened with neutral detergent or water.
Never use an abrasive cleaner, ether, thinner benzene, or other solvents.
Always make sure the instrument is completely dry before storing. Dry any moisture with a soft, clean
cloth.
FC-100 64848 90050 0404 (1a)
TRANSMITTION DATA TO THE PC
1
Install ActiveSync in your PC (if it is not already installed)
.
2
Connect the FC-100 to your PC with an interface cable F-25 as shown below
.
3
The FC-100 will give the prompt, “Connecting to Host”
.
4
The PC will prompt you to set up a partnership or set up as a guest.
5
Select the [NO] key to setting up as a guest.
6
Press the [Next] key.
Once a connection has been established, the ActiveSync window will appear on your PC.
7
Click the [Explorer] icon. You will then see the FC-100 file structure.
USB port (TYPE Mini-B)
PC
Interface(USB) cable F-25
FC-100
USB port (TYPE A)
Reference software for Connectivity
See the WEB page as follows.
http://www.microsoft.com/windowsmobile/
If your device had not recharged during several days, the battery will be running down, and you would lose all of data on the
device other than that in the "CF Card (internal CF card)".
In addition, you might perform hardware-reset by the hardware problem or software problem. In this case, you would lose all
data same as the above.
You can use Backup function of FC-100 in order to evade such kind of uneasiness. Your data will be restored to latest condi-
tion* automatically when rebooting by using the Backup function.
The Backup function saves all data files of RAM (except for OS files), registry file and additionally installed programs into
named "Backup" folder in the "CF Card".
Execute the Backup function
1
Tap the icon "Start"-"Settings"-"Control Panel"-"System"-"Backup". You can see the "RAM Backup" screen on Display.
2
Tap the "Backup" button. Backup function will start. Return to "RAM Backup" screen automatically, when the data back up has
been completed.
3
Tap the button "OK" on title bar. After that "RAM backup" screen will close automatically.
Set the Automatic Backup for every suspension
1
On the "RAM Backup" Screen, please check it 'ON' "Ram data will be backed up before suspension".(Factory setting is 'OFF' as
default)
2
Tap the button "OK" on title bar. After that, "RAM backup" screen will close automatically.
Set the restoration disabled after hard reset
1
On the "RAM Backup" Screen, check it 'OFF' the "Data restoration after hard reset."
(Factory setting is 'ON' as default)
2
Tap the button "OK" on title bar. After that, "RAM backup" screen will close automatically.
* Restoring former backed up data may be incomplete if you upgrade OS version.
* The conditions that you executed the backup function last.
* Backing up data may be incomplete if remaining capacity of "CF Card" is not enough.
Please make sure the remaining capacity of "CF Card" before proceeding to the data back up.
* Restoration will be impossible if you delete the "Backup" folder in the "CF Card".
PREPARATION FOR USE
Battery Charging
1
After installing the battery, plug the connector of AD-9B/
7C in the FC-100.
2
Plug the AD-9B/7C in an outlet. Then the charge LED
will light.
Charging is completed after approximately 5 hours.
The display can be turned on or off by the power key.
The charge LED of FC-100 will indicate charging
status;
Red ON
: Charging.
Green ON
: Charging completed.
Red Flashing
: Charging error.
Battery
Adjusting Touch Screen
1
Turn on the instrument after hard-reset or tap [Start], [Setting], [Control Panel], [Stylus], [Calibration], [Recalibrate].
2
Using a stylus pen, touch the center of the target.
3
After touching all targets(5 points), press [ENT] key or tap the display.
(Use an accessory stylus pen to touch a screen. Do not use neither a ball-point pen nor pencil.)
Stylus pen
Targets
Touch Screen
Note
1)Recharging should take place in a room with an ambient temperature range of +10°C to +40°C (+50°F to +104°F).
2)The battery source will discharge when stored and should be checked before using with instrument .
3)Be sure to charge a stored battery source every 7 days and store in a place at 30°C and below when it will not used
for a long period. If you allow the battery to be completely discharged, it will have an effect on the overall
performance for proper charging in the future.
4)The charger may develop heat while charging, there is no problem of it.
5)If charging is done at high temperature, charging time of the battery may take longer.
Interface Cable
AD-9B or AD-7C
Connector
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
TOPCON POSITIONING SYSTEMS, INC.
5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A.
Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON EUROPE B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com
TOPCON DEUTSCHLAND G.m.b.H.
Giesserallee 31, 47877 Willich, GERMANY
Phone: 02154-885-100 Fax: 02154-885-111 info@topcon.de
www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490 Fax: 33-1-47390251 topcon@topcon.fr
TOPCON ESPAÑA S.A.
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern, Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
TOPCON SCANDINAVIA A. B.
Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249
TOPCON (GREATBRITAIN) LTD.
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
survey.sales@topcon.co.uk laser.sales@topcon.co.uk
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381
Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
Unit 18, 4 Avenue of Americas Newington NSW 2127, Australia
Phone: 02-8748-8777 Fax: 02-9647-2926 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 02-440-1152~7 Fax: 02-440-1158
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra,
Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA
Phone: 03-42701068 Fax: 03-42704508
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road,
Shatin, N.T., Hong Kong
Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
TOPCON CORPORATION BEIJING OFFICE
Room 8A Poly Plaza Building, 14 Dongzhimen Nandajie,
Dongcheng District, Beijing, 100027, China
Phone: 10-6501-4191~2 Fax: 10-6501-4190
TOPCON CORPORATION BEIRUT OFFICE
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON.
Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
C/O Atlas Medical FZCO., P. O. Box 54304, C-25, Dubai Airport Free Zone,UAE
Phone: 971-4-2995900 Fax: 971-4-2995901
IRELAND OFFICE
Unit 69 Western Parkway Business Center
Phone: 01460-0021 Fax: 01460-0129
Lower Ballymount Road, Dublin 12, Lreland
Replacement of Battery
• When the battery is replaced, the data recorded in memory will be lost.
To protect the data, first execute “RAM Data Backup”, then replace the battery.
Note:
The instrument may develop heat while charging, there is no problem of it.
FCC conditions
This device complies with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
RAM DATA BACKUP
Charge LED
Battery terminal
Bluetooth™ and the Bluetooth™ logos are trademarks owned by
Bluetooth™ SIG, Inc., USA.