7. INSTRUMENT SETTINGS
(4) Range mode
Range mode settings are as follows.
Detail / High Speed / Low Power / Standard / Close
Please refer to the following for details.
The number of measured data may vary depending on the measurement distance or the selected
range mode in the circumstances noted below.
• In the case where the incident angle of the distance measurement laser toward the target
measurement object was narrow.
• In the case where the target was measured by using objects that have a multiple reflection effect
such as a mirror.
• In the case where a highly reflective object located close and facing toward the instrument is
measured.
(5) Pulse select
When the target measurement objects are in the foreground and background as shown below, the
distance of either object can be measured by changing the pulse selection.
• Depending on the reflection ratio of or the distance between the target measurement objects, it
might not be possible to measure the target even by switching from first to last or vice versa.
Range mode
Cycle of light emission
Laser class
Distance
Detail
120 KHz
Laser class 3R
Up to 100 m
High Speed
120 KHz
Laser class 3R
Up to 210 m
Low Power
48 KHz
Laser class 1M
Up to 210 m
Standard
60 KHz
Laser class 3R
Up to 350 m
Close
120KHz
Laser class 3R
Up to 40 m
Pulse Select : First
Pulse Select : Last
Target measurement
object (foreground)
Target measurement
object (background)
GLS-2000
Top View
Distance finder laser