83
15. WARNING AND ERROR MESSAGES
Type
Message
Description
Countermeasures
Scan Setting
H Interval too small.
Please set again
The starting point and end
point of the designated scan
range are too close together.
Designate a wider range.
V Interval too small.
Please set again
Scanning Error
An error occurred while
scanning.
Cannot scan the target.
Long press the power key and
restart the instrument. If it does
not work, remove both the inter-
nal and external batteries and
restart the instrument.
Window is dirty
Wipe clean.
Displayed when the instru-
ment detects that foreign
matter is attached on the
window and stops the task
temporarily.
Check and remove the attached
matter on the window before
resuming or stop operations.
Target Scan
Cannot find target
The target center cannot be
found.
The target may not be correctly
collimated or may have been
blocked during scanning.
Or, there may be a reflecting
object around the target.
Reconfirm the position and scan
again. If the error
persists, restart the instrument
and scan once again.
If correction is still not seen,
adjustment will be required.
Deviation seems to be large
Distance Dev: ** mm
Angle Dev : ** arcsec
The deviation can be
increased in bad weather
conditions or when the task
is interrupted for some rea-
son while scanning.
Mesurment failed
An error occurred during
target center measurement.
Battery
Battery Low!
The battery is low.
Or the battery may become
depleted while scanning.
Replace with fully-charged
batteries.
Coordinate
point import
Can not find data.
Please start over.
Displayed when there is no
usable data stored in the
selected CSV file.
Confirm the content of the
selected CSV file.
No coordinates are selected.
Please import csv file.
Displayed when you attempt
to import a coordinate point
name or a coordinate point
from a coordinate point list
which does not exist in the
instrument.
To import a coordinate point
name or a coordinate, import a
CSV file to the instrument by
pressing [List Import] in
advance.
This is not csv file.
Reading file failed.
Displayed when you have
selected a file which does
not have CSV extension on
the coordinate list registra-
tion screen.
Select CSV file for coordinate
list.
Exceeded the number of
registration.
Displayed if there are more
than 250 coordinate points in
the selected CSV file, which
is displayed on the coordi-
nate list registration screen.
From the first list to the 250th list
registered in the CSV file will be
imported into the instrument as
the coordinate lists.
List does not exist.
Please start over.
Displayed when you attempt
to delete a list while there is
no coordinate point list in the
instrument.
Import the coordinate point list
from a CSV file before deleting.
Camera
Can not determine exposure
value.
Scan is cancelled.
Displayed when an auto
exposure adjustment is not
complete.
Retake photographs of the
range or determine the expo-
sure value manually.