6-22
6 SPECIAL MODE (Menu Mode)
6.4.7 Setting RS-232C communication with external device
You can set the parameters for RS-232C communication with external device from parameters setting
menu .
The following parameters can be set.
ACK mode, CRLF and REC type are interlocked with the same items in the selecting mode.
Refer to 16 “SELECTING MODE”
Sample setting
STOP BITS: 2
Item
Selecting items
Baud rate
1200, 2400, 4800, 9600, 19200, 38400
Character bit/Parity
7/Even, 7/Odd, 8/None
Stop bit
1, 2
ACK mode
Standard , Omitted
CR,LF
ON, OFF
REC type
REC-A, REC-B
Factory setting
Baud rate:1200 baud, Character bit/Parity:7/Even, CRLF:OFF, REC
type: REC-A, ACK:Standard
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
↓
)
key twice to get the menu on page 2.
[MENU]
[F4]
[F4]
2
Press the [F1] key.
[F1]
3
Press the [F4] key twice.
[F4]
[F4]
4
Press the [F1] key.
The data previously set is shown.
[F1]
5
Press the [F3] key to select STOP BITS.
The data previously set is marked.
[F3]
6
Press the [F2](2) key to select stop bit 2, and press
the [F4](ENTER) key.
7
Press the [F4](ENTER) key.
[F2]
[F4]
MENU 3/3
F1:PARAMETERS 1
F2:CONTRAST ADJ.
P
↓
PARAMETERS 1 1/3
F1:MINIMUM READING
F2:AUTO POWER OFF
F3:TILT P
↓
PARAMETERS 1 3/3
F1:RS-232C
F2:SELECT COM
F3:BLUETOOTH P
↓
RS-232C 1/3
F1:BAUD RATE
F2:CHAR./PARITY
F3:STOP BITS P
↓
STOP BITS
[F1:1 ]
F2:2
ENTER
STOP BITS
F1:1
[F2:2 ]
ENTER