Calibration
Excavator Hitch
54
Excavator Indicate System
P/N: 1022461-01
6. With the attachment plumb, tap
Calibrate
from the
Calibrate Attachment Angle
screen
(Figure 73); tap
Next
to go to the
Calibrate Bucket Base
screen.
Figure 73: Calibrate Attachment Angle
7. Move the attachment so that the bottom of the attachment lays flat on the ground, and tap
Calibrate
; tap
Finish
to go to the
Excavator Attachments
screen (Figure 74).
Figure 74: Calibrate Attachment Base
Multiple Attachments
If a using a quick coupler to switch attachments, mount the sensor to the quick release mechanism,
or the DogBone, not the attachment. When calibrating multiple attachments, you must perform the
vertical and flat attachment calibrations for each applicable attachment; see “Attachment Edge” on
page 53.
If setting up multiple attachments of any kind, skip to “Multiple Attachments” .