Calibration
Excavator Hitch
55
Excavator Indicate System
P/N: 1022461-01
Tilt Bucket
1. On the GX Series display, tap the
Power Button
Control
Machine setup.
Select the
applicable machine file for the job and tap
Edit
. The
Configuration name/type
screen
appears.
2. Tap
Next
until you reach the
Excavator Attachments
screen, and then tap
New
to create a
new Tilting bucket, or tap
Edit
to calibrate an existing Tilting bucket.
3. Select
Tilting Bucket
from the drop-down menu, and enter the bucket
Width
and
Length
(Figure 75).
4. Enter a value for the tilt bucket
Length (3)
, and select a
Sensor ID
for the tilt bucket sensor.
Figure 75: Enter Tilt Bucket Measurements
5. Using a carpenter’s level adjust the bucket until the tilt pin is horizontal.
6. Using a carpenter’s level, adjust the cross slope of the bucket until the bucket is level.
7. In 3D-MC, tap the
Wrench
icon next to the
Sensor ID
.
8. Select the sensor’s
Orientation
based on this position (Figure 76).
Note that the Single-axis TS-i3 sensor orientation is only
label front / arrow right
or
label back / arrow right.
If using the Dual-axis TS-i3d, the orientation is
label up / arrow front
,
label up / arrow back
,
label up / arrow left
, or
label up / arrow right.