Setup V
e
rification
String Line Verification
62
Excavator Indicate System
P/N: 1022461-01
Record Bucket Positions with Boom and Stick Retracted
If a hub with a known position is available, use those coordinates as the reference. Otherwise, use
the first position as a reference. Compare each position to the reference. The difference should be
within ± 0.2Ft.
S
tring Line Verification
The following sections describe setting up a string line to test the sensor accuracy.
S
etup
1. Set a zero slope using a laser.
2. Set up a string line the length of the machine’s reach, and then set up the string level.
3. Utilize the measure slope feature to perform the following test. For more information on the
Measure Slope function, refer to the
3D-MC User's Manual P/N 1013510-01.
Bucket extended
Bucket mid-position
Bucket curled