Setup V
e
rification
LS-B10W Test
66
Excavator Indicate System
P/N: 1022461-01
6. If the values still match, check the secondary boom sensor (if used), and then the body sensor.
7. If the measurements compared against 3D-MC do not match, each sensor must be evaluated for
machine measurement or calibration errors.
L
S
-B10W Test
1. Set the Rotating Laser to transmit a flat plane beam.
2. Set flat string line, and measure the distance from the laser plane to the string line using a grade
rod with laser receiver.
Figure 84: Laser Plane to String Line Measurement
Distance from laser plane to string line:_________________________
3. Create a 0% Known Slope Surface in 3D-MC by tapping the
Topcon Logo button
Tools
Known Slope,
ensure grade is 0.00%, and
tap
OK
.
4. Place the LS-B10W in the laser plane, and press the
Zero to laser
button.
5. Set the
Elevation Set Point
equal to the distance from string to laser plane.