background image

Tilt detection function 

(

During communication with LS-B110W only)

Switching the tilt direction

The tilt direction can be changed.

1

Long-push the detective precision switch and the tilt switch at 
the same time.  The tilt direction mode setting changes in the 
following order: "Back and Forth," "OFF" and "Right and Left." 
At this time, the LED above the mark indicating the tilt direction 
will flash. The LED will not flash when the tilt detection function 
is switched OFF.

Switching the tilt precision

1

Short-push the tilt switch.  The tilt precision will change.  At 
this time,  the LED below the mark indicating the tilt precision 
will light up. 

Zero position setting for the tilt sensor

Before using the tilt detection function, set the zero position of the tilt 
sensor according to the directions below. The tilt direction must be set 
before setting the zero position.

1

Raise or lower the machine blade or arm where the LS-B110W 
is installed to position the cutting edge or bucket at the desired 
slope.

2

Long-push the tilt switch on RD-100W.  The tilt angle for the 
LS-B110W will set to 0

°

.

Tilt angles and display patterns

Tilt directions : Right and Left

Tilt directions : Back and Forth

Tilt indication will be displayed during laser detection and for 20 seconds after switch 
operation.

Changing the ON-GRADE position function

 (During communication with LS-B110W only)

The ON-GRADE position can be changed to the position where laser 
beam is detected. Using this function when installing the LS-B110W  
on the pole of the machine allows easy setting of the height at which 
the ON-GRADE will be displayed on the LS-B110W. The range in 
which the ON-GRADE position can be changed is ±75mm (total of 
150mm) from the center of the detective range.

In order to set the ON-GRADE position at high precision, set it while 
the laser beam is stable. When setting the ON-GRADE position while 
the laser beam is unstable (when using at a long-distance - more than 
150m - or when atmospheric condition is unstable due to air shimmer-
ing or other conditions), the sensor will automatically detect it and the 
LED indicating the failure will be displayed while changing the ON-
GRADE position.

1

Long-push the zero-set switch while detecting the laser beam.

The LED display and LCD display while changing the ON-

GRADE position

 
Cancellation the ON-GRADE position change

1

Long-push the zero-set switch when not detecting the laser 
beam.  The ON-GRADE position will be reset.

High precision
Normal precision

:   ±1°
:   ±2.5°

Flashes quickly

±5°

More than ±5°

Flashes slowly

Lights off

:  More than ±1°
:  More than ±2.5°

High precision
Normal precision

High precision
Normal precision

:   ±1°
:   ±2.5°

 

Flashes

7400 National Drive, Livermore, CA 94551, U.S.A.
Phone: 925-245-8300 Fax: 925-245-8599 www.Topconpositioning.com

3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329

Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-458-5077 Fax: 010-284-4941 www.topconeurope.com

 

Giesserallee 31, 47877 Willich, GERMANY
Phone: 02154-885-100 Fax: 02154-885-111  info@topcon.de
www.topcon.de

89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490  Fax: 33-1-47390251  topcon@topcon.fr 

Phone: 031-7109200 Fax: 031-7109249

Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
survey.sales@topcon.co.uk   laser.sales@topcon.co.uk

Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381
Phone: 65-6778-3456 Fax: 65-6773-6550  www.topcon.com.sg

77/162 Sinn Sathorn Tower, 37th Fl.,

Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 66-2-4401152~7  Fax: 66-2-4401158

No.D1, (Ground, Lower Ground & 1st Floor), Jalan Excella 2, Off Jalan Ampang
Putra, Taman Ampang Hilir, 55100 Kuala Lumpur, Malaysia
Phone: 60-3-42709866  Fax: 60-3-42709766

Block No.9, Kangding Street
Beijing Economic-Technological Development Area, Beijing, 100176, China
Phone: 86-10-6780-2799  Fax: 86-10-6780-2790

P. O Box293705, Office C-25(row C-2), Dubai Airport Free Zone, Dubai, UAE
Phone: 971-4-2995900 Fax: 971-4-2995901  marketing@Topcon.ae

Unit 69 Western Parkway Business Center

Phone: 01460-0021 Fax: 01460-0129

Lower Ballymount Road, Dublin 12, Lreland

7G

 

When changing the ON-GRADE position, the LED lights up 
for three seconds, as shown in the figure. The position where 
the laser beam is being detected will be the ON-GRADE 
position.

 

The LED display indicating beam position and the 
LED (1 green) in the center will flash.  The mark 
showing laser beam position on the LCD will flash.

 

When the ON-GRADE position change is cancelled, 
the LED (3 green) will flash for three seconds.

Specifications

Wireless communication 
range

:

20m
(May vary depending on obstacles between 
the two instruments and other conditions)

Power source

:

AA-size dry cells   3pcs. 

Continuous operating time
(+20

°

C/+68

°

F)

:

Approximately 40 hours
(Using alkaline manganese dry cells)

Operating temperature

:

-20

°

C~+50

°

C(-4

°

F~+122

°

F)

Water proof

:

IP66 (Based on the standard IEC60529)

Dimensions (W/D/H)

:

110x36x176(mm) (4.3

x1.4

x6.9

)

Weight (Without cells)

:

0.5kg (1.2lbs)

Detective angle, Detective precision and Laser detecting range may vary 
depending on rotating laser being used or atmospheric conditions.

Tilt direction mark : 
        Right and Left

Tilt direction mark :

           Back and Forth

Tilt precision mark :

              High precision

Tilt precision mark :

        Normal precision

The LED (1 green) lights up as shown in the figure 
for three seconds when the zero position is set.

The LED (2 red) flashes as shown in the figure for 
three seconds when you have failed to set the 
zero position.

The LED lights up as shown in the figure for three seconds 
when you have failed to change the ON-GRADE position. Be 
careful not to change the position at which the laser beam is 
detected and try setting once again.

31267 90113