43
(Example: Y axis)
4
Select Y axis by pressing the right arrow key.
Press the [ENT] key to lock.
5
“POSITION 1” display will flash and the instrument
will begin auto-leveling. After the auto-leveling is
completed, the “POSITION 1” light will turn on, then,
the rotary head rotates and emits laser beam. (Y-).
6
Turn on the power for the level sensor, and press
the detective precision switch to select the high
detection mode.
7
Check the position of the laser beam (Y-) on the
wall.
Move the sensor up or down until the LCD indicator
identifies the center of the laser beam.
8
After fixing the beam, press the [ENT] key.
The display will change to flashing “POSITION 2”.
Check the laser beam on the wall.
Fix the level sensor in the position
where the LCD indicator identifies
the center of the laser beam.
Press the [ENT] key after check.
POSITION 1
POSITION 2