39
Detective range (LS-70A/70B)
LS-70A
±1mm/±.0032ft
(2mm/.0064ft width)
±2mm/±.0064mm
(4mm/.013 ft width)
LS-70B
±1mm/±.0032ft
(2mm/.0064ft width)
±5mm/±.016ft
(10mm/.032ft width)
±10mm/±.033ft
(20mm/.066ft width)
±15mm/±.05ft
(30mm/.10ft width)
More than ±15mm/±.05ft
Laser sensor has been moved above or
below the laser beam.
Move sensor in direction of arrow to
receive laser.
Replacing Battery (LS-70A/70B)
1
Press the lid in the direction of the arrow
to lift.
2
Remove the battery and
replace with a new 9v
alkaline battery.
3
Press the lid down and
click to close.
Remote display with coil cord
(LS-70A option only)
Optional remote display connects to the back
of the LS-70A. The remote LCD display can
be positioned up to 5m (16 ft) from the laser
sensor.
Connector
Coil cord
Remote display