background image

Thank you for purchasing the TOPCON RL-H3CL Rotating Laser.
The RL-H3CL instrument has many unique features. For basic operation, rough level the instrument and press power switch. It
will self-level, then emit a rotating laser beam. 
For superior product performance, please read these instructions carefully and keep them in a convenient place for future ref-
erence.

GENERAL HANDLING PRECAUTIONS

Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.
When storing the instrument for long period, remove the batteries.
Always make sure instrument is dry before putting it in the carrying case. Never store a damp instrument. 

DISPLAY FOR SAFE USE

In order to ensure the safe use of this product, prevent any danger to the operator or others, or damage to property, impor-
tant warnings are placed on the product and inserted in the instruction manual. We recommend that you become familiar
with the meaning of these Warnings and Cautions before continuing.

INSTRUCTION MANUAL

ROTATING LASER

RL-H3CL

•Injury refers to hurt, burn, electric shock, etc.
•Physical damage refers to extensive damage to equipment and structure or furnishings.

Display

Meaning

WARNING

Ignoring or disregard of this display may lead 
to the danger of death or serious injury.

CAUTION

Ignoring or disregard of this display may lead 
to personal injury or physical damage.

CAUTION

• Use of controls or adjustment or performance of procedures other than those spec-

i

fi

ed herein may result in hazardous radiation exposure.

• Do not stand or sit on the carrying cases. 

It could overturn, causing injury.

• Do not use a damaged instrument case. 

It could accidentally open causing damage to the instrument or injury to people.

• Do not place yourself or a re

fl

ecting object in the path of the laser beam. If using the 

laser outside, avoid positioning it anywhere near eye level to avoid any possibility of 
it striking someone in the eye. If this should happen, visibility could be temporarily 
impaired, causing disorientation and possible accidental injury.

• Please note that the tips of tripod can be hazardous, be aware of this when setting 

up or carrying the tripod.

• Do not allow skin or clothing to come into contact with acid from the batteries, if this 

does occur then wash off with copious amounts of water and seek medical advice.

• Do not place instrument on unstable platform, surface or tripod.

If using tripod, make sure instrument is securely attached.

• Risk of injury by falling down a tripod and an instrument.

Always check that the screws of tripod are tightened.

Exceptions from Responsibility

1

The user of this product is expected to follow all operating instructions and make periodic checks of the product’s performance.

2

The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, conse-
quential damage, and loss of pro

fi

ts.

3

The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of pro

fi

ts by any disaster, (an earthquake, storms, 

fl

oods etc.), 

fi

re, accident, or an act of a third party and/or a usage in other than usual conditions.

4

The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of pro

fi

ts due to a change of data, loss of data, an interruption 

of business etc., caused by using the product or an unusable product.

5

The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of pro

fi

ts caused by usage other than explained in the user 

manual.

6

The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other prod-
ucts.

STANDARD PACKAGE COMPONENTS

Upon opening, make sure that all the followings are included.

1 RL-H3CL Instrument . . . . . . . . . . . . . . . . . . . . . . . . 1set
2 LS-70B/70C* Laser Sensor  . . . . . . . . . . . . . . . . . . 1set
3 Size "C" dry batteries (R14PU) . . . . . . . . . . . . . . . . 4pc.
4 9 volt dry battery (6F22/S-006P) . . . . . . . . . . . . . . . 1pc.
5 Carrying case  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1pc.
6 Instruction manual. . . . . . . . . . . . . . . . . . . . . . . . . . 1vol.
7 Model-6 Laser Sensor Holder . . . . . . . . . . . . . . . . . 1pc.

    * LS-70B is included for some markets instead of LS-70C.

Detect the on-grade position “---” by moving the Laser Sensor 
up and down. Directional arrows and audio signals assist in 
locating the on-grade position as the laser strikes the beam 
receiving window.  (Top of Laser Sensor is 40mm (1 9/16") 
from on-grade index for offset marking.) 

LS-70B:The indicators are located on front and back sides of the
              instrument.
LS-70C:The indicator is located only on front side.

Indicator

On-Grade precision switch

Two on-grade precision options are available, normal preci-
sion and high precision. By pressing this switch, the preci-
sion options are switched alternately. Con

fi

rm the precision 

choice by the indicator. (Normal precision is the default set-
ting each time the sensor is turned on. See LS-70B/70C 
Indicator diagram below.)

The power switch turns ON or OFF by pressing. If the power 
switch is turned ON, all signs will be displayed on the indica-
tor for a second with a beep sound.

Volume of the sensor buzzer can be alternately switched to
LOW/LOUD/OFF by pressing the switch.

Auto shut off function

The power will be turned off automatically if no laser beam 
is detected for approximately 30 minutes. (To turn on the 
laser sensor, press the power switch again.)

Power switch

Buzzer speaker
Buzzer sound switch

Beam receiving window

On-Grade
Index

LS-70B/70C
(Laser Sensor)

RL-H3CL

Turn the beam receiving window side 
towards RL-H3CL to detect the laser beam.

Protective glass

Rotary head

Laser beam emits from here.

Handle

Battery door

Battery door knob

Power switch

Turn the instrument ON or OFF.

Laser Safety

This product uses a visible laser beam, and is manufactured and sold in accordance with “Performance Standards for Light-
Emitting Products” (FDA/BRH 21 CFR 1040) or “Radiation Safety of Laser Products, Equipment Classi

fi

cation, Requirements

and User’s Guide” (IEC Publication 60825-1) provided on the safety standards for laser products.
As per the said standard, this product is classi

fi

ed as a  “Class ll Laser Product” or “Class 2 Laser Product”.

This is a simple product to operate and does not require training from a laser safety of

fi

cer.

In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer. 

Beam aperture

NOMENCLATURE AND FUNCTIONS

Battery power (Red LED)

Blinking:

The power is low, but laser is still usable. (Blinking 
continues for one minute.)

On Solid:

Dead batteries. Replace the batteries with new 
ones. (The lamp is solid for 

fi

ve minutes, then turned 

off automatically.)

Auto leveling (Green LED)

Blinking quickly:

Auto leveling is in process.

Blinking slowly:

Auto leveling is almost complete.

On Solid:

Auto leveling is complete.

Manual mode ON switch

ON:Push twice continuously.
OFF:Push once.

Height alert OFF switch

OFF:Push twice continuously.
ON:Push once.

Height alert OFF (Red LED)

Height alert does not function.

Manual mode ON (Red LED)

Auto leveling does not function.

Label

SAFETY CAUTIONS

WARNING

¥ There is a risk of fire, electric shock or physical harm if you attempt to disassemble or 

repair the instrument yourself.

This is only to be carried out by TOPCON or an authorized dealer, only !

¥ May ignite explosively.

Never use an instrument near 

fl

ammable gas, liquid matter, and do not use in a coal mine.

¥ Cause eye injury or blindness.

Do not stare into beam.

¥ Risk of fire or electric shock.

Do not use a wet battery.

¥ Battery can cause explosion or injury.

Do not dispose in 

fi

re or heat.

¥The short circuit of a battery can cause a fire.

Do not short circuit battery when storing it.

CLASSII LASER  PRODUCT

DIODE LASER 

WAVE LENGTH 630-685nm

1mW MAXIMUM OUTPUT

C A U T I O N

LASER RADIATION

DO NOT STARE INTO BEAM

CLASS

 

2

LASER PRODUCT

DO NOT STARE INTO BEAM

LASER RADIATION

154

152

150

153

151

138

136

134

132

139

137

135

133

131

131

149

147

148

146

HOLDER−6

HOW TO OPERATE

•Set the instrument to the tripod or smooth surface.
•Make sure instrument is roughly level (±3°).
•Press power switch (ON).

1

2

3

•Press power switch on laser sensor (ON).
•Select the precision mode by pressing the On-

Grade precision switch.

•Locate the on-grade position “---” by moving the

laser sensor up and down.

•Mark the position of On-Grade index. 

(Top of the Laser Sensor is 40mm [1 9/16"]
from index for offset marking.)

LS-70B/70C Indicator

High precision mode

Normal precision mode

Battery remaining display

Below grade indicator

Move the sensor up.
Audio signal:Lower pitch, slower frequency

On-Grade position

Audio signal:Continuous beep sound

Above grade indicator

Move the sensor down.
Audio signal:High pitch, frequent beep

Clamp Knob

Laser Sensor Holder

Laser Sensor

Using Laser Sensor On Rod 

EXAMPLES OF TYPICAL USE

Note
In manual mode

•Auto-leveling function is not active.
•Height alert function is not active.

Height alert function

(Safety lock system)

When auto-leveling and height 
alert function are active, after the 
laser beam emits for one minute, 
this function prevents the instru-
ment from operating if it is dis-
turbed. This insures accurate 
control. If the unit is disturbed, all 
lamps will blink except battery 
power lamp. The elevation (height 
of instrument) should be veri

fi

ed 

and re-established if necessary. 
This function is not active in the 
manual mode.

When using the Laser 
Sensor with other 
select Topcon lasers, 
these symbols alert 
user if laser batteries 
are low or if laser has 
been disturbed. 
These symbols are 
not active when used 
with RL-H3CL.

(1 9/16")

Level Vial

Reviews: